27
The server IP address and socket port would be connected in TCP
Server, TCP Client and UDP Client mode for a certain serial port.
□
□
□
Remote socket port
The server socket port would be connected in TCP Client and UDP
Client mode for a certain serial port.
□
□
□
Interface of serial I/O
RS23
2:
TxD, RxD for data stream, no flow control
RS232 (RTS/CTS
):
TxD, RxD for data stream, RTS/CTS for flow
control.
□
□
□
Baudrate
Baud Rate: 300 ~ 115.2K bps
□
□
□
Parity, Data bits, Stop bit
Parity: None, Even, Odd, Space, Mark.
Data Bits: 5, 6, 7, 8.
Stop Bit: 1 or 2.
□
□
□
Force off-line time
It is for setting the off-line time period of device will be taken when
there is no date input. The parameter can be from
“0 to 99”
and the
time unit is
“Minute”
.
□
□
□
Packet Collect Time
It is for setting a packet collecting period of the device serial port’s Tx
and Rx. The parameter can be from
“0 to 999”
and the time unit is
“mSec”
.
□
□
□
Serial
I /
O Port 2 (RS-232/422/485)
This converter device model is provided second serial port as RS-232/422/485
(Auto-Detect) interfaces for connecting the extension serial device.
□
□
□
Local Port ⁄ Socket Mode ⁄ Remote IP & Port
This converter device provides 1 socket connection port.
□
□
□
Port number
Summary of Contents for EX-9132C-2