background image

SSE232

-LE

Serial Server

www.exemys.com

Internet Enabling Solutions

User´s Manual

Summary of Contents for SSE232-LE

Page 1: ...SSE232 LE Serial Server www exemys com Internet Enabling Solutions User s Manual...

Page 2: ...lution to satisfy our customer needs For that reason the specifications and capabilities are subject to change without prior notice Updated information can be found at www exemys com Copyright Exemys...

Page 3: ...2 Access to configuration Web page 11 3 1 3 TCP Configuration Command Console 12 3 1 4 Serial Configuration Command Console 12 3 1 5 Configuration of Network Basic Parameters through the console 13 3...

Page 4: ...___24 Table 12 PROTOCOL command______________________________________________________________24 Table 13 Default Configuration______________________________________________________________30 Figures F...

Page 5: ...is manual are listed in the following chart Table 1 Acronyms Acronym Description ARP Address Resolution Protocol bps Bits per second HTTP HyperText Transfer Protocol IP Internet Protocol LAN Local Are...

Page 6: ...or any other device with a serial interface SSE232 LE is the interface between the equipment with serial communication and the Ethernet network acting as a transparent converter Figure 1 shows the co...

Page 7: ...onnection COM A is found in the DB25 DTE female connector as shown in figure 3 COM A can be configured as RS 232 RS 485 or RS 422 DB25 Connector COM A Data Indicator Led green Ethernet Connector Net I...

Page 8: ...3 COM A to PC cable 2 2 2 RS 485 and RS 422 Connection Use terminals TRX and TRX to connect SSE232 LE to a RS485 network And use terminals TRX TRX RX RX to connect SSE232 LE to a RS422 network TR 14...

Page 9: ...to operate It can be connected to a Hub or Switch with an standard network cable 2 3 1 Connection through a Hub or Switch A UTP network cable is used to connect SSE232 LE to the Ethernet through a Hub...

Page 10: ...guration parameters may be modified at any time using any of the methods mentioned above 3 1 1 IP Address Configuration SSE232 LE default configuration is IP 0 0 0 0 so when turned on it will search f...

Page 11: ...XX XX XX In Unix the command to add an entry to the ARP table is the following arp s 192 168 0 105 00 90 C2 XX XX XX Send a ping to the IP address you added to the ARP table on the previous step by e...

Page 12: ...ommand console SSE232 LE Exemys V2 0 Password SSE232 LE will ask for a Password You will then have three opportunities to enter your password After that the console will be blocked for 5 seconds befor...

Page 13: ...t sure close communication without typing the END command _ To change the netmask enter the following command netmask 255 255 255 0 Ok Netmask 255 255 255 0 NOTICE This parameter will be accepted upon...

Page 14: ...function either in Client Mode or in Server Mode 3 2 1 1 Server Mode If a COM socket channel is configured to function in server mode in a port configured by the user SSE232 LE will be on hold on that...

Page 15: ...on Password Both the TCP configuration console and the web page are protected by a password The device administrator may assign access key for these resources thus supplying safe access to SSE232 LE c...

Page 16: ...ugh the web page by executing the WEBCFG command Table 4 WEBCFG command Command Description WEBCFG E D Enables or disables configuration through web page E Enables D Disables 3 2 2 4 How to reset to m...

Page 17: ...ou may reset SSE232 LE by executing the RESET command Table 6 RESET command Command Description RESET Resets the SSE232 LE This command must be entered twice for SSE232 LE to reset 3 2 3 Configuration...

Page 18: ...an only packet On the other hand it incorporates a delay in the transmission of information which should be carefully treated according to the serial protocol in use If such protocol does not allow a...

Page 19: ...the maximum time allowed for inactivity may be configured Once this period of time lapses SSE232 LE will consider the connection terminated and will close it down This option can be disabled so the c...

Page 20: ...command Table 8 ARESET command Command Description ARESET E D Configures the Automatic Reset option for the channels in server mode E Enables D Disables 3 2 5 Server Mode Channel Configuration The SS...

Page 21: ...0000 Maximum time of inactivity allowed to the connection corresponding to the COM x after which the connection is terminated and the device returns to client waiting mode It is expressed in minutes 3...

Page 22: ...t Mode select C PORTx 1 65535 Client Port for the COM x IPSERVx aaa bbb ccc ddd Server IP address to which the COM x will connect PORTSERVx 1 65535 Server Port to which the COM x will connect INACTOUT...

Page 23: ...orks through a TCP connection in the port 999 Each command must end with the CR character ASCII 13 The system will answer if each command has been successfully executed of not 3 2 8 1 Supervision of C...

Page 24: ...You may select the transport protocol for the Ethernet interface Possible protocols are TCP and UDP The selection of the transport protocol affects all SSE232 LE channels Thus if you select the TCP pr...

Page 25: ...DP Client Channel IPSERV 255 255 255 255 IP 192 168 0 106 UDP Client Channel IPSERV 192 168 0 105 IP 192 168 0 107 UDP Client Channel IPSERV 192 168 0 105 IP 192 168 0 108 UDP Client Channel IPSERV 19...

Page 26: ...he client to be linked to that IP After that all the information received by the serial port will be transmitted to the client s IP If the client fails to send a packet to the server the server will n...

Page 27: ...www exemys com The Device Locator application must be running from any PC within the network where the Exemys devices to configure are installed Figure 11 Exemys Device Locator When the Device Locator...

Page 28: ...the device has a configured password You can type an IP Address Netmask and Gateway IP Address or you can click on the Use DHCP check box to make the device search a DHCP Server Click on the Ok butto...

Page 29: ...work It is second on and second off SSE232 LE is waiting for an IP address configuration ping or the CFG command to be entered It blinks like a beacon 90 of a second off and the remaining 10 on SSE232...

Page 30: ...char Disabled Window of time Disabled 0ms Mode Server Listen Port Server Mode 1000 Server IP Address Client Mode 192 168 0 99 IP Port Server Number Client Mode 1000 Inactivity Timeout Disabled COM Ty...

Page 31: ...or Any device with a serial RS232 485 422 port requiring an access to an Ethernet network RTS CTS DSR DTR DCD Embedded HTTP server password protected Telnet like console password protected Serial cons...

Reviews: