Table 11 - STA and RST commands
Command Description
Answer
STA<CR>
Shows the connection status of the sockets of
all the channels available (according to the
model)
STA,wxyz<CR>
w, x, y, z: they may be ‘1’ o ‘0’
1 = Connected
0 = Disconnected
RST:x<CR>
Resets the socket of channel x.
The channel can be:
A = COM A
B = COM B
C = COM C
D = COM D
Depends on the amount of available channels
in the SSE232-LE model
RST:x,OK<CR>
Channel x has been successfully reset
RST:x,ERROR<CR>
The channel x has not been successfully
reset or the channel is not available in
this model.
3.3 UDP Transport Protocol
You may select the transport protocol for the Ethernet interface. Possible protocols are: TCP and
UDP.
The selection of the transport protocol affects all SSE232-LE channels. Thus, if you select the TCP
protocol, all the channels will use this protocol. And the same applies to the UDP protocol.
To change the protocol through the SSE232-LE configuration Web Page:
Select “Network” from the menu, you will see the Network configuration page.
Select the Transport Protocol from the combo box.
Click on the “Send” button, so the SSE232-LE may take the changes.
You may also change the protocol by executing the PROTOCOL command through the command
console.
Table 12 - PROTOCOL command
Command
Description
PROTOCOL:(T|U)
Configures the network protocol for all SSE232-LE channels.
T = TCP
U = UDP