DHCP Lease: if “Yes”, then the device network parameters where obtained from a DHCP
server.
It is not necessary for the device to be properly configured. If the device is correctly connected
and working, it will be found by the Device Locator Application Program.
To refresh the grid, click on the “Query Network” button. This action will make the device Locator
to search any Exemys device in the network again.
You can change any of these basic network parameters within the Device Locator program.
To configure any Exemys device founded by the Device Locator:
Select the device in the grid and click on the
“Properties” button, or open the “Actions”
menu and select the “Properties” command.
You will see the Properties dialog box.
All Exemys devices provides a Remote
Configuration Password. This password is used
for the Web configuration page and remote
command Console in the device. Enter this
password in the “Enter current password” box
if the device has a configured password.
You can type an IP Address, Netmask and
Gateway IP Address or you can click on the
“Use DHCP” check box to make the device
search a DHCP Server.
Click on the “Ok” button so the Device Locator
sends this information to the device.
If the password is not correct, the Device Locator will show a “Error Response from MAC
Address 00-0B-FA-XX-XX-XX”. The device will not respond any message send by the Device
Locator software within the first 5 seconds after an incorrect password configuration attempt.
This is to avoid any brute force method to change the network parameters of the device.
If the device does not respond, the Device Locator will show a “No Response from Device”
message. Make sure the device is turned on and connected to the ethernet network.
The Exemys device will reset so the changes in the configuration take effect.
Click on the “Close” button to close the Properties dialog box.
After a few seconds the device being reset will answer again to the requests of the Device
Locator software. Click on the “Query network” button to refresh the grid and make sure the
parameters were changed.