SSE232-LE User’s Manual
Exemys
Summing up:
Enabled Automatic Reset: If a new client tries to connect to an already opened link (with or
without the same client) the previous connection will be aborted to allow the connection of
the new client.
Disabled Automatic Reset: It will prevent a new client to connect if there already exists an
open link on the Server Port.
You may configure the Automatic Reset Option through the SSE232-LE Web Page:
Select “Network” from the menu, you will see the Network configuration page.
Select the Automatic Reset Enabling from the combo box.
Click on the “Send” button, so the SSE232-LE may take the changes.
You may configure the Automatic Reset option through the command console by executing the
ARESET
command.
Table 8 - ARESET command
Command
Description
ARESET:(E|D)
Configures the Automatic Reset option for the channels in server mode
E = Enables
D = Disables
3.2.5 Server Mode Channel Configuration
The SSE232-LE channel configured in Server Mode will be on hold, waiting for a connection in a
specified port (configurable by the user).
If the connection is closed, the device will stay on hold, waiting for a new connection in that Port.
In Server Mode, the parameters for the channel must be configured as follows:
Mode: The mode for the channel must be Server Mode.
Port: This identifies the TCP Port to which the clients that wish to send information must
connect. The information sent go through the corresponding serial COM and vice-versa.
Inactivity Timeout: Time of inactivity of the link after which SSE232-LE will consider the
connection to the server terminated if no flow of information is detected.
www.exemys.com Rev.
1.0.3
Page20