61
Auxiliary Output
Ratings
Parameter
Description
Aux
Option
Min
Nom /
Typical
Max
Output Voltage (V)
Output voltage of the Auxiliary Output
5 V
4.85
5
5.15
12 V
11.6
12
12.4
Output Current (A)
Maximum output current for which the
Auxiliary Output is rated for operation
5 V
4.7
12 V
2
Output Power (W)
Maximum output power for which the
Auxiliary Output is rated for operation.
5 V
23.5
12 V
23.5
Ripple and Noise
Parameter
Description
Aux
Option
Min
Nom /
Typical
Max
Output Ripple (mV)
Amplitude of ripple measured at nominal
voltage and at 20 MHz Bandwidth
5 V
100
12 V
480
Output Ripple
Frequency (kHz)
Frequency of output ripple.
Both
Options
180
200
220
Regulation
Parameter
Description
Aux
Option
Min
Nom /
Typical
Max
Load regulation
(mV)
0
–
100% Load
5 V
100
12 V
240
Line Regulation
(mV)
85
–
264 Vac
5 V
15
12 V
36
Summary of Contents for CoolX1800
Page 29: ...29 ...
Page 71: ...71 CoolX1800 2 x Bulk Modules ...