44
Appendix 1: Detailed Output Specifications
Standard Modules (CmA-CmD)
Ratings
Parameter
Description
Module
Min
Nom /
Typical
Max
Output Voltage (V)
Output voltage range for which the module
is rated for operation
CmA
2.5
5
6
CmB
6
12
15*
CmC
15
24
28
CmD
28
48
58
Factory Setting
Accuracy (mV)
Maximum deviation from target output
voltage setting when CoolX is initially
configured.
CmA
10
CmB
10
CmC
20
CmD
40
Output Current (A)
Maximum output current for which
the module is rated for operation.
(Maximum output current to be
derated by 5% when used in parallel)
Co
o
lX600
CmA
21
CmB
15
CmC
8.33
CmD
4.17
Co
o
lX1800
CmA
30
CmB
23.3
CmC
12.5
CmD
6.25
Output Power (W)
Maximum output power for which the
module is rated for operation.
(Maximum output power to be
derated when CoolX is used in
ambient temperatures greater than
40
ᵒ
C
–
see Appendix 2: Thermal
Derating for further details)
Co
o
lX600
CmA
105
CmB
180
CmC
200
CmD
200
Co
o
lX1800
CmA
150
CmB
280
CmC
300
CmD
300
Capacitive Loading
(mF)
Maximum capacitive load of the module to
ensure monotonic startup (with no
additional load applied)
CmA
20
CmB
10
CmC
8
CmD
4.7
*Full Dynamic Specifications of the CmB module may not be met at full load when the CmB module is trimmed above 13 V
in the CoolX1800