66
𝑅
𝑉𝑇𝑅𝐼𝑀
=
47000(𝑉
𝑜𝑢𝑡
− 𝐹)
𝐹 + 5𝐾 − 𝑉
𝑜𝑢𝑡
Where:
Module
F
K
CmA
2.43
1.59
CmB
5.85
3.84
CmC
13.82
6.3
CmD
26.13
13.2
CmE
22.45
1.19
CmF
43.06
0.28
Please note that the upper range of remote trimmable voltage is limited by the potentiometer setting.
Remote Current Limit Setting (Using External Voltage)
Available On:
Standard Modules (CmA-CmD)
The current limit of the CoolMod can bet set by applying a control voltage Itrim across the Output Signal Connector (J100x)
pins Itrim (Pin 5) and Common (Pin 1 or Pin 3). The Itrim voltage required for the users desired current limit with the module
can be calculated using the following formula.
𝐼
𝑡𝑟𝑖𝑚
=
𝐼
𝑜𝑢𝑡
𝐾
Where:
Module
K
CmA
14.79
CmB
10.65
CmC
5.75
CmD
2.89
Summary of Contents for CoolX1800