Page - 20
5 Wire Reversal Rest At Ground Systems
differ from the Negative and
Positive Pulse systems as there are no relays or doorlock control unit. In this type
of system, the switches themselves supply the positive voltage directly to the
doorlock actuators, and, more importantly, provide the return ground path. The
important thing to remember is the wires in this system rest at ground, which means
that the wires must be "opened", or cut, to make the connections.
Examine the wires on the back of the switch. Normally five wires will be found-
one will be constant 12 volts positive, regardless of the switch's position; two wires
will be grounded regardless of the switch's position. Of the two remaining wires,
one will show 12 volts positive when the switch is pushed to "lock", and the other
will show 12 volts positive when the switch is pushed to "unlock".
DLS Red connector
plugs into Control
Unit
Green wire
to the "Motor"
side of the
cut “lock” wire
Blue wire
to the "Motor"
side of the
cut “unlock” wire
Cut both the “lock”
and “unlock” wires*
Brown wire
to the "Switch"
side of the cut
“unlock” wire
White wire
to the "Switch"
side of the
cut “lock” wire
Lock
Unlock
Driver
Doorlock
Switch
Lock
Unlock
Passenger
Doorlock
Switch
Cutting only one of two wires can cause
misleading test results. For example, if
only the “lock” wire is cut, the “switch”
side of the cut will show (+)12 Volts when
the primary switch is pushed to the "lock"
position and the “motor” side of the cut
will show (+)12 Volts when the primary
switch is pushed to the "unlock" position.
Passenger
Motors
Driver
Motors
DLS
Relay
Relay
5 Wire Reversal Doorlocks
using the Optional
DLS & 2 Relays
DLS Violet Wire
to Constant
(+)12 Volts
3 Wire Positive Pulse Systems
are very similar to the Three Wire Negative
Pulse system except the vehicle's doorlock switches use 12 volt positive pulses to
operate the vehicle's doorlock relays or control unit. Examine the three wires on the
back of the switch; if more than three, suspect a 5 Wire Reversal system. One will
be constant 12 volt positive, regardless of the switch's position. Of the two
remaining wires, one will show Positive when the switch is pushed to "lock", and
the other will show Positive when the switch is pushed to "unlock".
CONNECTION:
Several options are available for connecting to 3 Wire
Positive Pulse doorlocking systems- the DLP-P3 polarity reversal interface, the
DLS and two relays or the DLR-C or DLR-U. If driver's door unlock priority is
desired, use the optional DLS-3. The following diagrams show how to connect
either of the optional DLP-P3 or the DLS and 2 relay interfaces.
Page - 17
Doorlock Switch
DLP-P3 Blue wire to
switch “unlock” wire
DLP-P3 Green wire to
Switch “lock” wire
Vehicle's Doorlock
Relay Control Unit
Unlock
Lock
3 Wire Positive Pulse
Doorlocks using an
Optional DLP-P3
Polarity Converter
Door
Motors
D/U+
D/L+
DLP-P3 Red connector
plugs into the control
module’s Red DLS port
DLP-P3
Door
Motors
Doorlock Switch
Vehicle's Doorlock
Relay Control Unit
Unlock
Lock
+12V
3 Wire Positive Pulse
Doorlocks using an
optional DLS &
2 SPDT Relays
Relay
DLS
Relay
DLS Blue wire to
Switch “unlock” wire
DLS Green wire to
Switch “lock” wire
DLS Violet Wire
to Constant
(+)12 Volts.
DLS Brown & White wires
are not used in this system
DLS Red connector
plugs into the control
module’s Red port
Text continues on Page 20