background image

Page - 20

5 Wire Reversal Rest At Ground Systems

 differ from the Negative and

Positive Pulse systems as there are no relays or doorlock control unit.  In this type
of system, the switches themselves supply the positive voltage directly to the
doorlock actuators, and, more importantly, provide the return ground path.  The
important thing to remember is the wires in this system rest at ground, which means
that the wires must  be "opened", or cut, to make the connections.

Examine the wires on the back of the switch.  Normally five wires will be found-

one will be constant 12 volts positive, regardless of the switch's position; two wires
will be grounded regardless of the switch's position.  Of the two remaining wires,
one will show 12 volts positive when the switch is pushed to "lock", and the other
will show 12 volts positive when the switch is pushed to "unlock".

 

DLS Red connector

plugs into Control
                      Unit

Green wire

to the "Motor"

side of the

   cut “lock” wire

Blue wire
to the "Motor"
side of the
cut “unlock” wire

  Cut      both the     “lock”

  and     “unlock”        wires*

Brown wire

to the "Switch"

side of the cut

“unlock” wire

White wire

to the "Switch"

side of the

cut “lock” wire

Lock

Unlock

Driver

Doorlock

Switch

Lock

Unlock

Passenger

Doorlock

Switch

Cutting only one of two wires can cause
misleading test results. For example, if
only the “lock” wire is cut, the “switch”
side of the cut will show (+)12 Volts when
the primary switch is pushed to the "lock"
position and the “motor” side of the cut
will show (+)12 Volts when the primary
switch is pushed to the "unlock" position.

Passenger

Motors

Driver

Motors

DLS

Relay

Relay

5 Wire Reversal Doorlocks

using the Optional

DLS & 2 Relays

DLS Violet Wire

to Constant
(+)12 Volts

3 Wire Positive Pulse Systems 

are very similar to the Three Wire Negative

Pulse system except the vehicle's doorlock switches use 12 volt positive pulses to
operate the vehicle's doorlock relays or control unit.  Examine the three wires on the
back of the switch; if more than three, suspect a 5 Wire Reversal system. One will
be constant 12 volt positive, regardless of the switch's position.  Of the two
remaining wires, one will show Positive when the switch is pushed to "lock", and
the other will show Positive when the switch is pushed to "unlock".

CONNECTION:

  Several options are available for connecting to 3 Wire

Positive Pulse doorlocking systems- the DLP-P3 polarity reversal interface, the
DLS and two relays or the DLR-C or DLR-U.  If driver's door unlock priority is
desired, use the optional DLS-3.  The following diagrams show how to connect
either of the optional DLP-P3 or the DLS and 2 relay interfaces.

Page - 17

Doorlock Switch

DLP-P3 Blue wire to

switch “unlock” wire

DLP-P3 Green wire to

Switch “lock” wire

Vehicle's Doorlock
Relay Control Unit

Unlock

Lock

3 Wire Positive Pulse
Doorlocks using an
Optional DLP-P3
Polarity Converter

Door

Motors

D/U+

D/L+

DLP-P3 Red connector

plugs into the control

module’s Red DLS port

DLP-P3

Door

Motors

Doorlock Switch

Vehicle's Doorlock
Relay Control Unit

Unlock

Lock

+12V

3 Wire Positive Pulse
Doorlocks using an
optional DLS &
2 SPDT Relays

Relay

DLS

Relay

 DLS Blue wire to
Switch “unlock” wire

   DLS Green wire to

Switch “lock” wire

DLS Violet Wire

to Constant

(+)12 Volts.

DLS Brown & White wires

are not used in this system

DLS Red connector

plugs into the control

module’s Red port

Text continues on Page 20

Summary of Contents for AL-1010-EDP

Page 1: ...is to be printed with gray scale front cover this is a place marker cover Excalibur INSTALLATION INSTRUCTIONS COPYRIGHT 2009 OMEGA RESEARCH DEVELOPMENT INC FRONT COVER PRINTER S NOTE production front...

Page 2: ...ansceiver or Coaxial Antenna 22 Programming The Programmable Features 23 31 Programming Features 32 Programmable Features Matrix 33 Contents Omega Disclaims Any Responsibility or Liability In Connecti...

Page 3: ...le which is mounted upon completion of the installation and testing of the system Some of the wiring connections such as power ignition and starter interrupt are best made at the ignition switch harne...

Page 4: ...the vehicle Separate AL 1010 EDP In the case of the AL 1010 EDP or as optional parts for the AL 1510 EDP the separate Status Light and Valet Switch may be custom mounted inside the vehicle For the Sta...

Page 5: ...ystems and accept all Omega analog doorlocking accessories dual triple relay sockets or the modular clip on add on relay packs All Omega doorlocking data bus module accessories can be driven by this p...

Page 6: ...und is difficult to diagnose pressing the arm lock or disarm unlock button Only the output itself will stop pressing either button again will normally operate the system and at any time after the 28 s...

Page 7: ...ure Typically a total closure feature is when locking the vehicle s doors if the key in the door is held to lock for a period of time the vehicle will close all windows and the sunroof in addition to...

Page 8: ...s will flash 3 times instead of once Feature 17 Ignition Activated Anti Carjacking Protection Feature 21 III Button Operation Factory Default Setting 3rd Channel press arm lock button to program Thest...

Page 9: ...tion andnot the interior light operation Page 9 Secondary Wiring Harness 8 Wire Connector Brown Wire Positive Siren Output The Brown wire is a 1 Amp Positive output designed to operate the electronic...

Page 10: ...them for disarming confirmation to confirm remote starting and to attract attention while the system is activated CONNECTION Connect this wire to the vehicle s Positive 12 Volt parking light circuit...

Page 11: ...nition switch is turned on An exception to this would be if feature 8 is turned on and a door being open when the ignition switch is turned on The following feature 7 controls the automatic unlocking...

Page 12: ...12 The correct wire for a Positive switching type of dome light door jamb pin switch system will have 12 volts present when the doors are opened and chassis ground when the doors are closed CONNECTION...

Page 13: ...and closes the door This feature turns that operation on or off and with options of having Last Door Arming operate with or without also locking the doors when the system does arm SecureCode is a uni...

Page 14: ...3 Disarm Alarm Upon Trunk Release 14 Arming Delay 15 Steady Siren Output Pulsed Horn 16 Alarm Functions Bypass 17 Ignition Activated Anti Carjacking Protection 18 Door Activated Anti Carjacking Protec...

Page 15: ...he exposed inner end high in the dash or behind pillar trim for the best operating range Do not place the exposed end too close to metal structural parts of the vehicle The AL 1010 EDP can be upgraded...

Page 16: ...tch s wiring Page 21 The two later wires are both routed to the doorlock actuators and are connected to either end of the actuator s motor winding When the switch is pushed to one position one of thes...

Page 17: ...river Motors DLS Relay Relay 5 Wire Reversal Doorlocks using the Optional DLS 2 Relays DLS Violet Wire to Constant 12 Volts 3WirePositivePulseSystemsareverysimilartotheThreeWireNegative Pulse system e...

Page 18: ...Pin Secondary Harness Backup Battery Port Slide On Clip for optional modular Backup Battery Coaxial Antenna Cable Route end as high as practical in vehicle away from metal Note May not be present or m...

Reviews: