Design and function
Interfaces
66
099-000141-EW501
12.01.2016
19-pole connection assignments for mechanised welding interface (X6):
Pin Signal
shape
Circuit diagram
signal name
Function
A
Output
PE
Connection for cable screen
B
Input
Pulsen ein
Thermal pulse mode up to max. 50 Hz, fixed balance of
50%
C
Input
SYN_E
Synchronisation for master/slave operation
D
Output
IGRO Relais
Current flows signal
I > 0
Contact closed = welding current flowing
(forms contact with signal G)
E
Input
Not/Aus
Emergency stop for higher level shut-down of the power
source.
To use this function, jumper 1 must be unplugged on PCB
T320/1 in the welding machine.
Contact open
welding current switched off
F
Input
Sollwert Absenkstrom Control voltage specification for secondary current,
0-10 V (0 V = I
min
/10 V = I
max
)
G
Output
IGRO Relais
Current flows signal
I > 0
Contact closed = welding current flowing
(forms contact with signal D)
H
Output
Prozeßspannung Uist Actual welding voltage, measured on pin S,
0-10 V (0 V = 0 V, 10 V = 100 V)
J
Output
SYN_A E
Synchronisation for master/slave operation
K
Input SYN_A
C
L
Input Str./Stp.
Start/stop
welding
current, same as torch trigger.
Only available in non-latched operating mode.
+15 V = Start, 0 V
Stop
M
15V
Power
supply
+15 V, max. 75 mA
N
Input
Sollwert Hauptstrom
Control voltage specification for main current,
0-10 V (0 V = I
min
/10 V = I
max
)
P
Input
Sollwert Frequenz
Nominal frequency value
0-10 V (0 V= 50 Hz, 10 V = 0.1 Hz)
R
Input
Not/Aus
Emergency stop for higher level shut-down of the power
source.
To use this function, jumper 1 must be unplugged on PCB
T320/1 in the welding machine.
Contact open
welding current switched off
S
Output 0V
Reference
potential
T
Output
Prozessstrom Iist
Welding current, measured on pin S,
0-10 V (0 V = 0 A, 10 V = 1000 A)
U
Input
BR. KOLL. 1
Emergency shut-down collision prot24 V
V
Output
BR. KOLL. 2
Emergency shut-down collision protection