Design and function
Organising welding tasks (Mode "JOB Manager")
56
099-000141-EW501
12.01.2016
5.20.5 Resetting JOBs 1-128 to the factory setting (Reset All JOBs)
Operating
element
Action
Result
Display
x x
Select JOB Manager mode
Press until the “VOLT”
signal light is on
2 sec.
Select JOB Manager mode
3 x
Switch from “Load JOB” to “Reset All JOBs”
• ON = Reset all JOBs to factory settings
• OFF = Do not reset JOBs
1 x
All JOBs reset to factory settings, machine
switches back to Display mode.
Current value and JOB
number displayed
5.20.6 Exit JOB Manager without changes
The user is in the JOB manager menu and wants to exit without making any changes:
Operating
element
Action Result
Display
2 sec.
Machine switches back to Display mode
The JOB can be adjusted individually.
Current value and JOB
number displayed