Rectifying faults
Resetting welding parameters to the factory settings
099-000125-EW501
29.9.2022
69
7.4 Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
To reset the welding parameters or machine settings to the factory settings, select parameter
in the
service menu
> see 5.8 chapter
.
7.5 Software version of the machine control
The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu
> see 5.8 chapter
.
7.6 Vent coolant circuit
Figure 7-1
• Switch off the machine and fill the coolant tank to the maximum level.
• Unlock the quick-connect coupling with a suitable tool (connection open).
To vent the cooling system always use the blue coolant connection, which is located as deep as
possible inside the system (close to the coolant tank)!
Figure 7-2
• Position a suitable collection container for collecting the escaping coolant at the quick-connect coup-
ling and switch on the machine for approx. 5s.
• Lock the quick-connect coupling by pushing back the locking ring.