Design and function
Machine configuration menu
60
099-000125-EW501
29.9.2022
Display
Setting/selection
Welding torch cooling, post-flow time
Setting 1–60 min. (ex works 5 min.)
Time-based power-saving mode
> see 5.7 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
= disabled or numerical value 5-60 min..
Operating mode switching via interface for automated welding
------- Non-latched
------- Special non-latched
Re-ignition after arc interruption
> see 5.2.3.3 chapter
------- JOB-dependent time (ex works 5 s).
------- Function disabled or numerical value 0.1–5.0 s.
Expert menu
Automatic gas post-flow
-------- function on (factory setting)
------- function off
activArc voltage measuring
-------- Function enabled (ex works)
------- Function disabled
Error output to interface for automated welding, contact SYN_A
------- AC synchronisation or hot wire (ex works)
------- Error signal, negative logic
------- Error signal, positive logic
------- AVC (Arc voltage control) connection
Gas monitoring
Depending on where the gas sensor is situated, the use of a pilot static tube and the
welding process monitoring phase.
------- Function disabled (ex works).
------- Monitoring during the welding process. Gas sensor between gas valve and
welding torch (with pilot static tube).
------- Monitoring prior to the welding process. Gas sensor between gas valve and
welding torch (without pilot static tube).
------- Permanent monitoring Gas sensor between gas cylinder and gas valve (with
pilot static tube).
Automation menu
3
Fast take-over of control voltage (automation)
3
-------- Function enabled
------- Function disabled (ex works)
Orbital welding
3
------- Function disabled (ex works)
-------- Function enabled
Orbital welding
3
Correction value for orbital current
Service menu
Any changes to the service menu should be agreed with the authorised service person-
nel.
Reset (to factory setting)
------- Disabled (ex works)
------- Reset the values in the machine configuration menu
------- Complete reset of all values and settings
Resetting is performed when exiting the menu (
).