5.3.8 Expert menu (MMA)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
The setting ranges for the parameter values are summarised in the Parameter overview section.
EXIT
ENTER
4s
4s
Figure 5-34
Display
Setting/selection
Expert menu
Hotstart current
Hotstart time
Pulse current
> see 5.3.7 chapter
Pulse balance
Pulse frequency
5.4 Remote control
The remote controls are operated on the 19-pole remote control connection socket (analogue).
5.4.1 RT1 19POL
Functions
• Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
5.4.2 RTG1 19POL
Functions
• Infinite setting of the welding current (0% to 100%) depending on the main current
preselected at the welding machine