Design and function
Machine configuration menu
099-000157-EW501
16.10.2014
69
5.12.8
spotarc / Spotmatic configuration
EXIT
ENTER
+
l
0
Figure 5-35
Display
Setting/selection
Lock JOB menu
Protect welding parameters from unauthorised access
Settings
Settings for machine functions and parameter displays
Spotmatic
Function switched off
Spotmatic
Function switched on
Exit the menu
Exit
Setting spot time
• on = Short spot time (5 ms - 999 ms, 1 ms- steps)
• off = long spot time (0,01 s - 20,0 s, 10 ms- steps)
Long spot time
Setting of 0.01
–-20.0 s (10-ms steps)
Separate process activation
The welding process has to be reactivated for every arc ignition by pressing the torch
trigger.
Permanent process activation
The welding process is activated by pressing the torch trigger once. The following arc
ignitions are initiated by shortly touching the tungsten electrode against the workpiece.
Exit the menu
Exit