Machine control
– Operating elements
Overview of control sections
099-00T400-EW501
21.10.2016
9
3.1.1
Control section A
Figure 3-2
Item Symbol
Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 3.2 chapter
2
Push-button gas test / rinse hose package
> see 4.1.1 chapter
3
Operating mode/power-saving mode push-button
--------- Latched
> see 4.1.7.2 chapter
------- Non-latched
> see 4.1.7.3 chapter
------ spotArc spot welding procedure
– signal light turns
green
> see 4.1.7.4 chapter
------ spotmatic spot welding procedure
–signal light turns red
> see 4.1.7.5 chapter
-------- Press button for long interval to put machine into power-saving
mode
> see 4.4 chapter
.
Activate one of the operating elements to reactivate.
4
Pulsing push-button
> see 4.1.10 chapter
------ Automated pulsing (frequency and balance)
------- Signal light turns green: Thermal pulsed TIG welding/MMA pulse welding
------- Signal light turns red: Metallurgical pulsed TIG welding (kHz pulsing)/average
value pulsing
--- Special TIG AC
5
Welding current polarity/tungsten balling push-button
---- Signal light turns green: DC welding with negative polarity on the electrode
holder or welding torch.
---- Signal light turns red: MMA DC welding with positive polarity on the electrode
holder
> see 4.2.5 chapter
.
---- Alternating current welding/alternating current forms
> see 4.1.14 chapter
- Tungsten balling current
> see 4.1.3 chapter