Welding procedure
Machine configuration menu
68
099-00T400-EW501
21.10.2016
Display
Setting/selection
Setting the system of units
------- Units of length in mm, m/min. (metric system)
------- Unit of length in inches, ipm (imperial system)
Machine configuration (second part)
Settings for machine functions and parameter display
Foot-operated remote control ramp function
> see 4.1.15 chapter
------- Welding current rises to the specified main current level in a ramp function (ex
works)
------- Welding current immediately jumps to the specified main current level
Foot-operated remote control responsiveness
> see 4.1.15.1 chapter
------- Linear responsiveness (ex works)
------- Logarithmic responsiveness (better control of lower welding currents)
Tungsten balling with RT AC remote control
------- Function disabled
------
Function enabled (in addition, the "AC balance" rotary knob at the RT
AC remote control has to be turned to the left stop) (ex works)
Tungsten balling (old variant)
------- Function enabled
------- Function disabled (ex works)
Welding current polarity switching
------- polarity switching at the RT PWS 1 19POL remote control (ex works)
------- polarity switching at the welding machine control
spotmatic operating mode
> see 4.1.7.5 chapter
Ignition by contact with the workpiece
------- Function enabled (ex works)
------- Function disabled
Spot time setting
> see 4.1.7.5 chapter
------- Short spot time, setting range 5 ms to 999 ms, increments of 1 ms (ex works)
------- Long spot time, setting range 0.01 s to 20.0 s, increments of 10 ms (ex works)
Process activation setting
> see 4.1.7.5 chapter
------- Separate process activation
------- Permanent process activation (ex works)
Torch cooling mode
------- Automatic operation (ex works)
------- Permanently enabled
------- Permanently disabled
Welding torch cooling, post-flow time
Setting 1
–60 min. (ex works 5 min.)
Time-controlled power-saving mode
> see 4.4 chapter
• ---------- 5 min.–60 min. = time until activation of power-saving mode when inactive.
• ---------- off = switched off
Expert menu
AC average value controller
------- Function enabled (ex works)
------- Function disabled