Design and function
Machine configuration menu
099-005313-EW501
02.09.2015
67
5.14 Machine configuration menu
5.14.1 Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold the "sequence parameter" push-button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by pressing the "sequence parameter" push-button.
• Set or change the parameters by turning the "welding parameter setting" rotary knob.
EXIT (Exit the menu)
• Press the "gas test/flushing" push-button (switch machine off and on again).
ENTER
EXIT
+
NAVIGATION
l
0
D YN
t2
t1
D YN
t2
t1
m/min
AMP
Figure 5-34
Display
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Time-based power-saving mode
• 5 min.–60 min. = Time to activation of power-saving mode in case of inactivity.
• off = inactivated