Design and function
TIG welding
58
099-005313-EW501
02.09.2015
5.9.4
Further welding parameters
• Preselection: Select TIG JOB 127- See 5.9.3 Welding task selection chapter.
ENTER
3 s
EXIT
3 s
NAVIGATION
m/min
AMP
DY N
t2
t1
DY N
t2
t1
Figure 5-27
Display
Setting/selection
Gas pre-flow time
0.0 s to 20.0 s (0.1 s increments)
Ignition current
0% to 200% of the welding current (1% increments)
Upslope time
0.0 s to 20.0 s (0.1 s increments)
Downslope time
0.0 s to 20.0 s (0.1 s increments)
End current
0% to 200% of the welding current (1% increments)