Design and function
MIG/MAG welding
099-005313-EW501
02.09.2015
41
5.7.9
Further welding parameters
Validity of the settings.
Spot time, pause time and wire feed speed settings apply to all JOBs. Throttling effect/dynamics,
gas post-flow time, gas pre-flow time and wire burn-back correction are stored for each JOB
individually.
Changes are stored permanently in the JOB that is currently selected.
If required, these parameter values can be reset to the factory settings- See 7.3 Resetting welding
parameters to the factory settings chapter.
5.7.9.1 Choke effect / dynamics
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Set choke effect/dynamics.
Setting range:
40:
Arc hard and narrow, deeper
fusion penetration.
-40:
Arc soft and wide.
5.7.9.2 Gas post-flow time
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Adjusting the gas post-flow time.
Setting range:
0.0 s to 20.0 s in increments of 0.1 s