Design and function
Power-saving mode (Standby)
099-005546-EW501
7.12.2020
51
Display
Setting/selection
Dynamic power adjustment
> see 7.5 chapter
Time-based power-saving mode
> see 5.6 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
= disabled or numerical value 5-60 min..
Arc detection for welding helmets (TIG)
Modulated waviness for better arc detection
------ Function enabled
------ Function disabled
Service menu
Any changes to the service menu should be agreed with the authorised service
personnel.
Software version of the machine control
Version display
5.6 Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 4.3 chapter
for a
prolonged time or by setting a parameter in the machine configuration menu (time-controlled power-
saving mode
)
> see 5.5 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the
machine is ready for welding again.