Design and function
MMA welding
099-005546-EW501
7.12.2020
41
5.3 MMA welding
CAUTION
Risk of crushing and burns!
When changing stick electrodes there is a risk of crushing and burns!
• Wear appropriate and dry protective gloves.
• Use an insulated pair of tongs to remove the used stick electrode or to move welded
workpieces.
5.3.1 Connecting the electrode holder and workpiece lead
Figure 5-24
Item Symbol Description
0
1
Electrode holder
2
Connection socket for "+" welding current
Electrode holder or workpiece lead connection
3
Polarity selector plug, welding current cable
• Connect to the park socket.
4
Workpiece
5
Connection socket, “-” welding current
Electrode holder or workpiece lead connection
• Insert the polarity selection plug in the park socket and lock in place by turning to the right.
• Insert the electrode holder plug and workpiece lead into the welding current socket depending on
application and lock in place by turning to the right. The corresponding polarity will be based on the
information of the electrode manufacturer on the electrode packaging.