Design and function
Special parameters (advanced settings)
82
099-005504-EW501
20.11.2015
Switching programs with the standard torch trigger (P8)
Special latched (latched absolute program sequence)
• Cycle 1: absolute program 1 is run
• Cycle 2: absolute program 2 is run after completion of "tstart".
• Cycle 3: absolute program 3 is run until the "t3" time has elapsed. The program then switches
automatically to absolute program 4.
Accessory components such as remote controls or special torches may not be connected!
Program switching at the wire feed unit control is disabled.
Figure 5-43
Specific latched special (n cycle)
In the n cycle program sequence, the unit starts in the 1st cycle with start program P
start
from P
1
In the second cycle, the machine switches to absolute program 2, once the start time "tstart" has elapsed.
Tapping switches to other programs (P
A1
to max. P
A9
).
Figure 5-44