Design and function
Special parameters (advanced settings)
099-005504-EW501
20.11.2015
77
Display
Setting/selection
Display mode for Up/Down welding torch with one-digit 7-segment display (two
keys)
0 = normal display (ex works)
program number/JOB or welding performance/welding voltage correction is shown
1 = alternating display
display switches between program number and welding method
Program limitation
Programs 1 to max. 15
Ex works: 15
Special cycle in the special latched and non-latched operating modes
0 = normal (previous) non-latched/latched (Ex works)
1 = WF3 cycle for non-latched/latched
Enable special jobs SP1 to SP3
0 = no enabling (Ex works)
1 = enabling of Sp1-3
Correction operation, threshold value setting
0 = correction operation switched off (Ex works)
1 = correction operation on
"Main program (PA)" flashing
Program changeover with standard torch
0 = no program changeover (Ex works)
1 = special latched
2 = specific latched special (n cycle active)
Lat. and sp. lat. tapping start
0 = no latched tapping start (Ex works)
1 = latched tapping start possible
One or two-wire feed operation
0 = single operation (Ex works)
1 = dual operation, this unit is the "master"
2 = dual operation, this unit is the "slave"
Special latched tapping time
0 = tapping function switched off
1 = 300ms (Ex works)
2 = 600ms
JOB list changeover
0 = task-oriented JOB list
1 = actual JOB list (Ex works)
2 = actual JOB list, JOB changeover activated via accessories
Lower limit remote JOB changeover
Lowest JOB that can be selected using PowerControl 2 torches.
Lower limit: 129 (Ex works)
Upper limit remote JOB changeover
JOB range of the POWERCONTROL2 torch
Upper limit: 169 (Ex works)
HOLD function
0 = HOLD values are not displayed
1 = HOLD values are displayed (Ex works)
Block JOB mode
0 = Block JOB mode not enabled (Ex works)
1 = Block JOB mode enabled
Program selection with standard torch trigger
0 = no program selection (Ex works)
1 = program selection possible