Design and function
Special parameters (advanced settings)
78
099-005504-EW501
20.11.2015
Display
Setting/selection
Mean value display for superPuls
0 =
Function switched off.
1 = Function switched on (ex factory).
Predefined pulse arc welding process in the PA program
0 =
Predefined pulse arc welding process in the PA program is disabled.
1 =
If the superPuls and welding process switching functions are available and
activated, the pulse arc welding process is always executed in the main
program PA (ex factory).
Predefined absolute value for relative programs
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set
relative to the main program (P
A
) or in an absolute manner, as desired.
0 =
Relative parameter setting (ex factory)
1 =
Absolute parameter setting
5.17.1.1 Reset to factory settings
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
Action
Result
Switch off welding machine
Keep the button pressed
Switch on welding machine
Release the button, wait about 3 seconds
Switch off welding machine and restart in order to put the changes into
effect