Operating the machine control
Machine configuration (system)
30
099-00L105-EW501
07.06.2019
Operating mode switching at welding start (P27)
With the selected
4-cycle-Special mode, the user can determine by the time of the torch trigger operation
in which operating mode (4-cycle or 4-cycle-Special) the program sequence shall be carried out.
Hold torch trigger (longer than 300 ms):
Program sequence with
operating mode
4-cycle-Special (stan-
dard).
Tap torch trigger: Device changes to operating mode
4-cycle.
Error threshold of electronic gas flow control (P28)
The set percentage value is the error threshold; if it is undershot or exceeded, an error messa-
ge
> see 7.3 chapter
is displayed
.
5.4.5 Control
Menu item / parameter
Value
Comment
Operation without wire feeder is possib-
le
(This parameter controls the system
behaviour depending on the connected
wire feeder)
No (factory
setting)
The wire feeder (WF) can be changed during
operation.
Operation without a connected wire feeder is
not possible.
Yes
The welding system can be operated without a
wire feeder connected.