Set special latched tapping time (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
JOB list switching (P12)
Value Name
Explanation
1
Real JOB list
JOB numbers correspond to the actual memory cells. Every job can
be selected, there will be no memory cells if the selection will be skip-
ped.
2
Real JOB list,
JOB switching active
Like real JOB list. In addition JOB switching with appropriate accesso-
ry components such as a function torch is possible.
Creating user-defined JOB lists
An associated memory area, in which switching with accessory components such as a function
torch between JOBs is possible, is created.
• Set special parameters P12 to "2".
• Set switch "Program or Up/Down Function" to “Up/Down" position.
• Select existing JOB, which comes as close as possible to the desired result.
• Copy JOB to one or more destination JOB numbers.
If JOB parameters still need to be adjusted, select destination JOBs one after the other and adjust para-
meters individually.
• Special parameters P13 to the lower limit and
• Adjust special parameters P14 to the upper limit of the destination JOBs.
• Set switch "Program or Up/down function" to position "Program".
With the accessory component JOBs can be switched in the specified range.
Copying JOBs, "Copy to" function
The possible target range is between 129 - 169.
• First configure special parameter P12 to P12 = 2 or P12 = 1!
Copy JOB by number, see corresponding operating instructions ("Control").
By repeating the last two steps, the same source JOB can be copied to multiple target JOBs.
If the control does not register any user activity for longer than 5 seconds, the parameter display is shown
once more and the copy process is complete.
Lower and upper limit of JOB remote switching (P13, P14)
The highest and lowest JOB numbers which can be selected using accessory components, such as the
PowerControl 2 torch.
Avoids an accidental changeover into undesirable or undefined JOBs.