Program switching with standard welding torch (P8)
Special latched (latched absolute program sequence)
• Cycle 1: absolute program 1 is run
• Cycle 2: absolute program 2 is run after completion of "tstart".
• Cycle 3: absolute program 3 is run until the "t3" time has elapsed. The program then switches automa-
tically to absolute program 4.
Accessory components such as remote controls or special torches may not be connected!
Program switching at the wire feed unit control is disabled.