15
6.0 In s ta llation an d fir st o p eration
6.0 Installation and first operation
Authorized personnel
• The installation and first start of operation may only be
conducted by qualified personnel.
• Work on the electric system may only be performed by
professional electricians.
WARNING
Electric shock and moving parts hazards
Serious injury or death can be caused by touching live electrical
components and by unexpected movement of the actuator.
Be sure the system’s power supply is off and actuator is locked
out before installing.
WARNING
Danger if restarted without authorization!
When correcting faults, there is danger of the energy supply being
switched on without authorization. This poses a lifethreatening
hazard for persons in the danger zone.
Therefore:
• Prior to starting work, switch off the system and safeguard
it from being switched on again.
WARNING
Risk of injury and material damage due to incorrect installation
of the optional devices!
Therefore:
• Optional devices, in particular components that are part of a ret-
rofitting, may only be installed in accordance with their respective
instructions (circuit diagram).
• The electromagnetic compatibility must be tested for the routing
and appropriate measures must be carried out and as described
in the device’s operating manual.
6.1 Installation location
• Adhere to the technical data for operating conditions
(⮑ 11.0 Appendix, page 25).
• Install in a location where the actuator is not exposed to
strong UV radiation or corrosive or explosive air media.
6.2 Installation
The CAHB-10 linear actuator can be attached over two ele-
ments, via the front rod end (1) and the trunnion mount (2)
(the trunnion has two options: pins and bushings).
1. Connect the front rod end and trunnion mount to appro-
priate elements of the application. Adjustments of the
rod end are not allowed!.
1
2
Fig. 7
NOTE
Information concerning the dimensions of the drill holes for
fastening bolts can be found in the respective data sheets.
(⮑ ?? Appendix, page ?).
WARNING
Risk of injury and device damage due to insufficient fastening!
Only use fastening bolts and secure them adequately. Do not use
screws to install. Never loosen or otherwise manipulate screws on
actuator or options.
2. Ensure the applied force on the linear actuator is always
concentric with the axis of the actuator (⮑ Fig. 8).
Fig. 8