8.0 M a inten a n c e
8.0 Maintenance
Personnel
• The maintenance work described herein can be performed
by the operator unless otherwise indicated.
• Some maintenance tasks should only be performed by
trained personnel, qualified personnel, or exclusively by
the manufacturer; specific reference will be made in each
case in the description of the respective maintenance task.
DANGER
Electrical shock hazard
Incorrect maintenance can result in serious injury, death or
damage.
Only professional electricians should work on electrical systems.
DANGER
Danger if restarted
When correcting faults, there is danger of the energy supply being
switched on without authorization. This poses a life-threatening
hazard for persons in the danger zone.
Therefore, follow the precautions below:
• Prior to starting work, switch off the system and be sure it is
locked out.
8.1 Spare parts
The CAHB-10 linear actuator is not designed for repair work
by the customer. All warranty and service claims become
void without notice if any screws on the linear actuator have
been manipulated.
WARNING
Safety hazard caused by wrong spare parts!
Wrong or faulty spare parts can adversely affect safety and cause
damage, malfunctions or total failure.
Therefore, follow the precautions below:
• Spare parts in/on the actuator may only be replaced by Ewellix.
The actuator must be dismounted and sent to the manufac-
turer to replace any spare parts.
8.2 Maintenance plan
Maintenance tasks that are required for optimal and trou-
ble-free operation are described in the sections below.
If increased wear is detected during regular inspections,
shorten the required maintenance intervals according to the
actual indications of wear.
Linear actuator CAHB-10 maintenance plan
Interval
Maintenance work
To be carried
out by
Daily
Check actuator for visible damage
Operator
(⮑ 8.3.3 Check of visual condition,
page 22)
Operator
Clean off dust and dirt if necessary
(⮑ 8.3.1 Cleaning, page 22)
Operator
Monthly
Function check of operating features
and safety features
(⮑ 8.3.2 Inspections and readings,
page 22)
Qualified
personnel
Check tight fit of the actuator to the
hinge head. Tighten if necessary
Qualified
personnel
Annually Check connection for tight fit
Professional
electrician
As
suggested
by
processor
Conduct visual inspection of the
condition of the permanent safeguard
and the routing of the supply and
control cable within the application.
Cable routing elements may not be
loose or broken.
NOTE
If the linear actuator is used outside of the environmental conditions
specified earlier in this manual, check such components once a
month for any changes such as oxidation or sedimentation.