16
CAHB -1 0 s eries
WARNING
Risk of injury and material damage due to incorrect
installation!
During installation, do not subject the actuator to side-impact or to
turning forces.
3. During installation, make sure that the linear actuator is
not blocked in its movement over the entire stroke.
4. During installation, be sure that the motor cable is not
squeezed, clamped or pulled.
5. Connect linear actuator to power supply (⮑ 6.4 Con-
nect to power supply, page 16).
6. Ensure that none of the supply or control cables can be
pinched by the kinematics of the application or by the
linear actuator during the extension or retraction.
6.3 Inspections prior to
first operation
Prior to the first operation, a professional electrician must
perform and document the following tests and readings:
• Check visual condition
• Function check of operating features and safety features
• Reading of protective conductor resistance
• Reading of leakage currents
• Reading of insulation resistance
NOTE
Additional information concerning inspections and readings
(⮑ 8.0 Maintenance, page 19).
6.4 Connect to power
supply
DANGER
Electrical shock hazard
Incorrect installation can result in serious injury, death or damage.
Only professional electricians should work on electrical systems.
1. Connect cable to electric grid.
2. Actuator performs the extending and retracting as de-
fined in table 1.
Table 1
Cable
(Red)
Cable
(Black)
Actuator
(Standard)
I
–
+
Extending
II
+
–
Retracting