3722-IG-002 Installation and User Manual
February 6, 2019
18
Configuring J1772 Cable Operation
You now need to test cable operation, and then set it to lower to the ADA height of 48 inches from the ground each time a
charging session is initiated.
Testing Cable Operation
Note: The following operation assumes all steps with a remote Payment Module have been completed. If your 3722 does
not use a Payment Module, you will need to either push the ON button on the wall switch to release the cable prior to
pulling it, or the Remote FOB.
1.
Observe the Data Router on the front of the EVSE (Figure 14). You should observe that only the blue Power LED is
lit. Either use the Payment Module to initiate a charging session, or press the wired or wireless ON button or
Remote FOB. The yellow Connect LED starts blinking.
2.
Press and hold the switch on the J1772 connector (Figure 15), and lower the charging cable from the charger out to
the desired length. Release the switch and wait.
3.
After one minute, the cable will retract automatically.
Setting the Cable Lowering Height for ADA
1.
Set Switch 6 on the top of the Data Router to ON (Figure 16). The cable drops slightly and the blue and yellow LEDs
on the front of the Data Router start flashing.
2.
Press and hold the switch on the J1772 connector (Figure 15) until the charging cable lowers to a height of 48 inches
from the ground (ADA height, Figure 3).
3.
Set Switch 6 to OFF. The cable automatically retracts, the yellow LED turns off and the blue LED stays solid.
4.
To test, start a charging session, and ensure the cable drops to 48 inches from the ground.
Figure 14 Figure 15 Figure 16
OFF
ON
Press and Hold
Switch to
Extend Cable