EVS Broadcast Equipment SA
55
Take
The GPI contacts not only can be used as GPI contact but also can be
assigned as Take contact. The menu item is called
GPI_n-Take
.
Where n is the amount of GPI pools in the product. Every pool can only
have one Take contact. There will be no restrictions in assigning the
contact to a GPI pool and Take function at the same time. The values
will be 1 to x. When assigning a take pin to a pool set to
Prio_Latched
mode, the pool will behave the same as when set to
Prio
mode with a take pin assigned. This is because the take pin
overrules the latched functionality of the
Prio_Latched
mode.
Debounce time
The input contacts need to be debounced to assure signal stability. The
debounce time can be set in the
GPI-DebounceTime
object in a range
of
1-40
ms. This value will be applied to all contacts. In software
implementations setting a custom debounce time is not supported due to
technical limitations.
Summary of Contents for Synapse U4T100
Page 1: ...4K 3840X2160 ULTRA HD 4 WIRE TOOLBOX WITH OPTIONAL DOLBY E PROCESSING ...
Page 67: ......
Page 68: ......