PatternSpeed
Sets the speed of the test-pattern (see settings
Inp_SelA
and
Inp_SelB
) animation between 0 (still) and 15 (fast). Default is 1.
Input_loss_A
Input_loss_A
determines what the output of outputs A is in
case of lost input:
Freeze:
a capture of the last good field or frame.
Colorbar:
a color bar
Zoneplate
: a zone plate
Black:
a black output.
Grey:
a grey output.
Green:
a green output.
Freeze 1 sec:
a freeze of the last field or frame for 1
second. After 1 second the output framework is disabled.
Freeze 5 sec:
Same as Freeze 1 sec, only holding the
freeze frame/field for 5 seconds.
Backup-B
: switch to input B as output.
The default setting is
freeze
.
Input_loss_B
Input_loss_B
determines what the output of outputs B is in
case of lost input. Same values as
Input_Loss_A
are possible.
INSERTER
This card can insert several data values in the VBI of the outputs.
With the following settings you can choose what you want to insert.
Timecode_ins
Here you can set if the time code on the inputs should be copied to
the outputs (
on
), or to copy the time code from input 1 to input 2
(
Copy 1 => 2
), or to copy the time code from input 2 to input 1
(
Copy 2 => 1
). You can also turn
off
time code insertion.
Default is
on
.
VITC_Ln_In
With this setting you can select what line of the input you want to
copy the VITC data from (only when input is SD). Can be any line
between line 7 and line 22. Default is line 19.
VITC_Ln_Ctrl
Here you can choose whether you want to select the line, to where
you want to copy the timecode data to, manually (
manual
) or use
the information in the
ATC_DBB
package to select the lines
(ATC_DBB package contains information about the line duplication
as well). Default is
Manual
.
Summary of Contents for Synapse 2GF100/110