106
SYSTEM ANALYSIS
DYNAMIC TESTS
DYNAMIC TESTS
Cylinder Drop Tests
Use the
Evinrude Diagnostics
software
Dynamic
Tests
to momentarily disable one cylinder while
the outboard is running.
•
The Dynamic Ignition test disables the ignition
and fuel injection circuits to a cylinder.
•
The Dynamic Fuel test momentarily disables
one fuel injector circuit.
By dropping one cylinder, RPM and running qual-
ity changes can be compared for each cylinder.
IMPORTANT:
Test the outboard at the RPM
where the problem is occurring. Use the test pro-
cedures to identify inconsistencies in voltages and
cylinder performance. Once a circuit has been
identified as malfunctioning, inspect all related
wiring and connections. Check all voltage inputs
and grounds; and perform resistance tests for all
circuits before replacing any suspect components.
Dynamic Tests
can be used with:
•
A timing light to determine how other cylinders
are affected by one cylinder being “dropped”; or
•
A voltmeter to check voltage changes on electri-
cal circuits.
IMPORTANT:
DO NOT misinterpret tests run at
IDLE. The idle speed controller in the
EMM
com-
pensates to maintain a constant IDLE speed. The
Dynamic Tests
screen includes a function to tem-
porarily disable the idle controller.
Fuel Control Adjustment
Use this test is to help identify a cylinder that may
be too rich or too lean. This feature should not be
used by itself to identify a faulty injector.
Evinrude Diagnostics
software allows temporary
adjustments to the fuel flow characteristics of the
injectors. Factory fuel flow settings are restored
when power to the
EMM
is returned to OFF.
Test the outboard at the RPM where the problem
is occurring.
If the outboard run quality improves with a fuel
control adjustment, eliminate other possibilities
before replacing an injector:
•
Refer to
•
Refer to
IMPORTANT:
DO NOT misinterpret tests run at
IDLE. The idle speed controller in the
EMM
com-
pensates to maintain a constant IDLE speed.
Inductive Amp Meter Test
Use an inductive amp meter to monitor battery
charging and current flow. Identifying erratic
amperage in a circuit can be used to isolate a
problem component.
Dynamic Tests Screen
006773
006774
Summary of Contents for E75DPLSCB
Page 1: ...2008 SC E TEC 75 90 P N 5007527 75 90 HP 5007527 Service Manual ...
Page 2: ......
Page 231: ...POWERHEAD POWERHEAD VIEWS 229 11 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Page 232: ...230 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Page 233: ...POWERHEAD POWERHEAD VIEWS 231 11 Front ...
Page 234: ...232 POWERHEAD POWERHEAD VIEWS Rear ...
Page 235: ...POWERHEAD POWERHEAD VIEWS 233 11 Top ...
Page 302: ...S 2 ...
Page 349: ...2008 SC E TEC 75 90 P N 5007527 75 90 HP 5007527 Service Manual ...