EMX Series Multiframes
Page - 6
Revision 1.6
2.4. MOUNTING
The EMX1-FR requires a 19” x 1.75” x 18.75” (483 mm x 45mm x 477mm) space, the EMX3-FR requires
a 19” x 5.25” x 15.75” (483 mm x 133 mm x 400 mm) space and the EMX6-FR requires a 19” x 10.5” x
15.75” (483 mm x 260 mm x 400 mm) space. To securely fasten the frame to the equipment rack, make
sure that all four mounting screws on each mounting rail are tightened securely.
Note: The EMX6-FR, EMX3-FR and EMX1-FR have front mounted cooling fans
and require that the area below is flush so that there is sufficient room to open
the frame completely to be able to remove the modules.
After the unit has been installed in a rack, all cards in the frame should be checked to ensure they are
fully seated within the frame. This is best accomplished by simply pushing (simultaneously, with moderate
force) on each card’s top and bottom insertion/extraction levers. This step should be repeated any time
the frame is shipped, or relocated within a facility.
2.5. POWER
2.5.1. Power Cord
Power should be applied by connecting a 3-wire grounding type power supply cord to the power entry
module on the rear panel of each power supply. For use in North America, the power cord should be a
minmum 14AWG wire, type SVT marked VW-1, maximum 2.5m in length. For use outside North America
use a power cord approved for the country of use with a minimum 1.00mm
2
wire size.
CAUTION – To reduce risk of electric shock, grounding of the ground pin of the
mains plug must be maintained.
Summary of Contents for EMX Series
Page 2: ...This page left intentionally blank ...
Page 6: ...EMX Series Multiframes Page ii Revision 1 6 This page left intentionally blank ...
Page 10: ...EMX Series Multiframes Page 2 Revision 1 6 This page left intentionally blank ...
Page 22: ...EMX Series Multiframes Page 14 Revision 1 6 This page left intentionally blank ...