EMX Series Multiframes
Page - 18
Revision 1.6
5.1.2. The IEC 60417-6042 Lightning Flash Symbol
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the
presence of uninsulated “Danger voltage” within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
CAUTION – SHOCK HAZARD
5.1.3. IEC 60417-6172 Multiple Power Sources Symbol
The multiple power source symbol with multiple power cords is intended to alert the users that all power
sources should be disconnected to avoid shock hazards
CAUTION – DISCONNET ALL POWER SOURCES
5.2. CHANGING THE FUSES (NOT APPLICABLE TO EXM1)
Check that the line fuse is rated for the correct value marked on the rear panel.
Never replace with a fuse of greater value.
The fuse holder is located inside the power entry module. To change the fuses, pull out the fuse holder
from the power entry module using a small screwdriver. The fuse holder contains two fuses, one for the
line and one for the neutral side of the mains connection. Pull out the blown fuse and place a fuse of the
correct value in its place. The correct fuse rating is marked on the rear panel near the power entry
module.
Fuse Rating:
10 Amps, 250 Volt ceramic time delay, 5 x 20 mm
5.3. REPLACING THE POWER SUPPLY
Each power supply is a complete assembly and includes the power supply cooling fan and one frame
cooling fan. In the event that the power supply or one of the fans malfunctions, you will need to replace
the power supply assembly with a spare one while the failed assembly is being repaired.
Summary of Contents for EMX Series
Page 2: ...This page left intentionally blank ...
Page 6: ...EMX Series Multiframes Page ii Revision 1 6 This page left intentionally blank ...
Page 10: ...EMX Series Multiframes Page 2 Revision 1 6 This page left intentionally blank ...
Page 22: ...EMX Series Multiframes Page 14 Revision 1 6 This page left intentionally blank ...