Auto PID Select:
automatically choose the PIDs for each audio stream, based on Auto
Program Sel Mode.
•
Manual PID Select:
manually select PIDs for each audio stream.
Auto Program Sel Mode:
This parameter allows the user to set how the decoder will select a program
for decoding, when programTuningMode is set to auto.
•
First Program In PAT:
select audio PIDs from the first program will be chosen.
•
Lowest Program Num:
select audio PIDs from the lowest program will be used.
•
Specific Program Select:
will pick audio PIDs from specific program, specified by Program
Number Select control for decoding.
Program Number Select:
This parameter allows the user to select the program that is going to be
decoded. This is only applicable when
Program Tuning Mode
is set to
Auto PID Select
. Range for
this value can be set from 0 to 65535.
Video PID Select:
This parameter allows the user to select which video PID will be embedded by the
decoder into the video input, and can only be applied when
Program Tuning Mode
is set to PID
Select. Range for this value can be from 2 to 8190. When this setting is applied, if any of the selected
PIDS have been duplicated the user will be alerted with an ‘error’ message.
Note: 0, 1, and 8191 are reserved PIDS in MPEG so they are not included within
the value range.
Audio PID Select:
This parameter allows the user to select which audio PID will be embedded by the
decoder into the video input, and can only be applied when
Program Tuning Mode
is set to PID
Select. Range for this value can be from 2 to 8190. When this setting is applied, if any of the selected
PIDS have been duplicated the user will be alerted with an ‘
error
’ message.
Note: 0, 1, and 8191 are reserved PIDS in MPEG so they are not included within
the value range.
PCR PID:
This parameter allows the user to set the PID for PCR data being sent on ENC J2K and ENC
10bit 4:2:2 H264. Range for this value can be from 16 to 8190.
VANC PID:
This parameter allows the user to set the PID for VANC data being sent on ENC J2K and
ENC 10bit 4:2:2 H264. Range for this value can be from 16 to 8190.
PID Configuration:
This parameter sets the method to configure the PID. If it is pre-defined, then all
PID controls will be greyed out. The second method allows the user to manually configure them.