3.3.10 System error process (Schematic presentation
)
E43
E42
E39
E40
E41
Encoder error
Internal drive
SW error
Internal drive
SW error
Display not
detected
Display
communication
error
Replace
motor / wiring
Instal correct
display
Replace flexprint
cable
Install
correct PCB
Replace
display
Replace PCB (control unit)
E50
E53
E54
E55
E57
E56
Abort welding
open lever
Timeout
sealing
mechanism
Timeout
sealing process
Performance
limitation
(AUTO)
Timeout 10s
Tensioning
(AUTO)
Strap torn or
slipped
Incorrect sealing, repeat
Reduce
tensioning
force
Repeat tensionng
Replace opera-
ting lever switch
Insert the
strap again
Check / clean mechanics
Question the application
Replace cam
switch
or wiring
Clean or replace
tension wheel /
tooth plate