3.3
Error lists
The following summary shows the errors to be detected by the strapping device
3.3.1
Tension process error
No.
Process error
System response
Signalling
Rectification
A10
Tension button pressed without releasing
the tension
No tensioning
(A1) Short beeping
tone
Insert strap
A13
Trigger, tension button or sealing button
pressed during the tensioning process
[AUTO]
No tensioning
(A1) Short beeping
tone
A14
Permissible number of cycles exceeded
[MAN]
No (more) tensioning
(A1) Short beeping
tone
Tension again
A15
Tensioning process timeout
Cancel tensioning
process
(A2) 2x short beeping
tone
Tension again
A16
Trigger switch pressed during clamping
process
Cancel tensioning
process
A2) 2x short beeping
tone
Retensioning
A18
Limit performance [MAN, SEMI]
Cancel tensioning
process
(A2) 2x short beeping
tone
Retensioning
3.3.2
Sealing process error
No.
Process error
System response
Signalling
Rectification
A20
Sealing button (S5) activated without
release
No sealing
(A1) Short beeping
tone
Insert and tension
the strap
3.3.3
Processing error “Insert strap”
No.
Processing error
System response
Signalling
Rectification
A11
Tensioning button (S1) pressed while
trigger pulled
No tensioning
(A1) Short beeping
tone
A21
Sealing button (S1) pressed while trigger
pulled
No sealing
(A1) Short beeping
tone
3.3.4
Processing error battery
No.
Processing error
System response
Signalling
Rectification
A11
Battery temperature too low (derating)
Tensioning level will be
reduced
Symbols &
flash, force display
flashes
Increases auto-
matically at higher
battery temperature
Evers GmbH Graf-Zeppelin-Str. 10 46149 Oberhausen T49 208 99475-0 T49 208 99475-31 [email protected] eversgmbh.de