CHAPTER 10 HACCP ALARMS
Possible alarms are visualized on the first line on the lower part of the Display with symbol
next to them
10.1 Active HACCP alarm list
Recorded alarms are listed in the ALARM_SERVICE_CONFIGURATION MENU. Their presence is
signalled on the main screen by icon
.
With unlocked keyboard (chapter 9.2.6)
Push the MENU
①
key for 5 seconds to access configuration menu; select SERVICE, then ALARMS
(see SERVICE section)
10.2 Alarms and signals
In addition to the alarm buzzer and the ALARM symbol, all alarms generate signals indicating the
alarm type, displayed as follows:
VISUALIZED ALARM
POSSIBLE CAUSES
CAUSES/SOLUTIONS
Damaged probe1
Internal temperature/humidity probe
failure
Replace probe
Damaged probe2
Internal temperature/humidity probe
failure
Replace probe
Damaged probe3
Evaporator probe failure
Replace probe
Minimum temp. alarm
Temperature is below set minimum
- Too cold premises
- Too wet product
Maximum temp. alarm
Temperature is above set maximum
- Too hot premises
- Refrigerating unit failure
Low humidity alarm
Humidity is below set minimum
- Humidity probe failure
- Heating unit failure
High humidity alarm
Humidity is above set maximum
- Humidity probe failure
- Refrigerating unit failure
Power failure alarm
Power has been interrupted for more
than 15 minutes
Check electrical connections
Open door alarm
Door has remained open for more than
15 minutes
Close the door
Overheated condenser alarm
Condenser temperature has exceeded
the set maximum
- Dirty condenser
- Condenser fan failure
- Condenser probe failure
Blocked compressor alarm
Condenser temperature has exceeded
safety temperature
-Check condenser fan
-Reset: turn off the device, then turn it
on again
10.5 Remote management and remote control (Opt.)
A TTL Modbus port for connection to the module and a link to use EVconnect, EPoCA or BMS apps
are available on the thermoregulator (see remote management and remote control manual)
CHAPTER 11 NOISE LEVEL
The refrigerated cabinet is designed and constructed so that risks resulting from the emission of
airborne noise are reduced to the minimum level (see technical information).