![Everbilt PCP10001-VSP Use And Care Manual Download Page 9](http://html1.mh-extra.com/html/everbilt/pcp10001-vsp/pcp10001-vsp_use-and-care-manual_2442649009.webp)
PRIMING PUMP
Release all pressure from filter, pump, and piping system; see the filter owner’s manual. In
a flooded suction system (water source higher than pump), pump will prime automatically
during suction and discharge valves are opened.
If the pump is located above the normal pool water level, remove ring and trap assembly,
and fill trap and pump with water. Clean and inspect O
-
ring; then reinstall on trap cover.
Replace trap cover assembly on trap, then rotate clockwise to tighten cover.
NOTICE
:
Tighten ring and cover assembly by hand - do not use tools. Pump priming time
will depend on the vertical distance and length of the suction line. The pump is designed to
prime at 10 ft. or less. If the pump does not prime, make sure that all valves are open, and
that the suction pipe is submerged. Verify there are no leaks in the suction lines.
ROUTINE MAINTENANCE
The only routine maintenance needed is the inspection and cleaning of the trap basket. Debris or trash that
collects in the basket will choke off water flow through the pump.
Before attempting to clean the basket:
Stop pump, close valves in suction and discharge, and release pressure from system.
WARNING
:
Hazardous suction can trap hair or body parts, causing severe injury or death.
Do not block suction.
Remove the ring and cover assembly by turning counterclockwise. If necessary, tap
handles gently with a rubber mallet.
Remove the basket and clean. Inspect holes in basket for blockage. Clean the basket with water and
replace in trap. Verify that the basket is oriented correctly in pump housing.
Clean and inspect lid O-ring; then reinstall the ring and cover assembly.
Prime the pump (see priming instructions).
DRAINING THE PUMP
To avoid dangerous or fatal electrical shock hazard, turn OFF power to the motor before draining pump.
Pump down water level below all inlets to the pool.
Remove the trap cover.
Drain the basket housing and pump housing through the drain plugs.
Clean the pump and basket, then replace cover assembly.
Be sure motor is kept dry and covered.
NOTICE
:
Tighten trap cover by hand only.
STORAGE/WINTERIZING:
WARNING
:
Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to
anyone nearby. Use only a low pressure (below 5 PSI), high volume blower for purging the pump, filter, or piping.
For outdoor/unprotected installations:
Enclose entire system in a weather proof enclosure.
To avoid condensation/corrosion damage, allow ventilation; do not wrap system in plastic.
Use a 40% propylene glycol/60% water solution to protect pump to -50° F (-46° C).
NOTICE
:
Allowing pump to freeze will damage pump and void warranty!
NOTICE
:
Use only non-toxic antifreeze. Do not use automotive antifreeze. It is highly toxic and may damage plastic components in the system.