Pre-Installation (continued) 

4 IN. PUMP DESIGN AND OPTIMUM PERFORMANCE 

The 4 in. submersible well pumps sold in retail outlets are designed to pump 10 gallons per minute (10 GPM), which is the average size 
home’s use of water per minute. Larger homes will require larger pumps. 4 in. pumps are built with multiple pumping stages, i.e., 6-10 
stages, each lifting water to the next stage and to your application. Typically, the deeper the well, the more stages and more motor 
horsepower are required to lift the water. The impellers rotating in each stage need to operate in the middle of the stage. Operating above 
or below middle may cause the impeller to rub on other stage components, either shortening pump life and/or using excess energy (amp 
draw). 

PROPER 4 IN. PUMP SELECTION 

The proper well depth and horsepower for 10 GPM 4 in. submersibles are as follows: 

HP 

GPM  PUMP DEPTH IN WELL 

1/2 

10

 

60-100

 ft.

 

3/4 

10

 

100-175

 ft.

 

10

 175-250

 ft.

 

 

 

NOTE: 

In irrigation applications, i.e. small farms, the stages are designed to pump 20 GPM and the depth of water as follows: 

 

HP 

GPM  PUMP DEPTH IN WELL

20 

 

VOLTAGE 

4 in. submersible pumps are offered in 230V. Be sure the voltage of the pump you select matches the voltage of the well. 

NUMBER OF PUMP WIRES AND CONTROL BOXES 

4 in. pumps are offered in either 2 wire or 3 wire (the number of wires running from the pump motor). 

 

2-wire motors have 3 wires running from the motor - 2 to provide electric service and 1 ground wire. The motor controls are in the 
motor in the well. 

 

2-wire motors are typically used in wells less than 300 ft. in depth and 3-wire motors are used in deeper depths. 

 

Some users prefer their motor controls be readily available for service (3-wire and control box mounted near tank), while others 
find it unnecessary. 

 

3-wire motors have 4 wires running from the motor - 3 to provide electric service and 1 ground wire. These motors require a motor 
control box mounted on the wall near your water tank. 

 

3-wire installations will be more expensive. For example, your wire has more strands in it (4 vs. 3) and they are sold separately. 

 

 

NOTE: 

Control box voltage and horsepower must match pump voltage and horsepower. 

 

PUMP 

CONTROL BOX

HP 

VOLTAGE

HP 

VOLTAGE

1/2 

230 

1/2 

230

3/4 

230 

3/4 

230

230 

230

 

CONFIRMATION OF SELECTION 

Knowing the above and prior to removing and reinstalling your 4in. pump, please confirm the following: 

 

The correct HP for the depth the pump will sit in the well. 

 

The correct GPM (gallons per minute) for your well. 

 

The correct voltage. 

 

The correct number of wires. 

 

The correct control box (if applicable). 

60-100

 ft.

 

Summary of Contents for EFSUB10-122HD

Page 1: ...rovement needs Thank you for choosing Everbilt Item 1001 092 349 1001 092 255 1001 092 261 1001 092 264 1001 092 483 1001 092 258 1001 092 273 Model EFSUB5 122HD EFSUB5 123HD EFSUB7 122HD EFSUB7 123HD...

Page 2: ...cause cracking in plastics Use only Teflon tape when sealing joints in plastic pipe or connecting pipe to thermoplastic pumps WARNING California Proposition 65 Warning This product and related accesso...

Page 3: ...ranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to r...

Page 4: ...ches the voltage of the well NUMBER OF PUMP WIRES AND CONTROL BOXES 4 in pumps are offered in either 2 wire or 3 wire the number of wires running from the pump motor 2 wire motors have 3 wires running...

Page 5: ...ons for wire splicing instructions Permanently ground the pump motor and control box before connecting the power cable to power supply Connect the ground wire to the approved ground first and then con...

Page 6: ...Wire Cable 60 Hz Wire Size HP Volt Wire Size AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371...

Page 7: ...olor coding when connecting control box Yellow to Y Red to R Black to B Single phase 2 wire connections 2 wire pumps have two power supply wire Black and one ground wire Green Control box is not requi...

Page 8: ...1 1 2 in 38 mm on each side of the joint Make four passes with the tape When finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the w...

Page 9: ...or body and tighten by hand for a strong waterproof splice POWER SUPPLY WIRE INSTALLATION 1 To test submersible momentarily no more than 30 seconds connect it to the proper power supply Power supply f...

Page 10: ...low the procedure below when starting the pump for the first time NEVER start a pump with the discharge completely open unless you have done this procedure first 1 Connect a pipe elbow a short length...

Page 11: ...ill void the warranty Protect the pump and entire piping system including pressure tank from freezing PRE CHARGED PRESSURE TANK HOOKUP This diagram shows a typical submersible installation with a pre...

Page 12: ...kPa Control box 3 wire models only Electrical Disconnect Box Pre Charged Tank Ground Level Conduit or Sleeve Plastic Pipe Adapter Power Cable Nylon Tape Cable Splices Centering Guide Plastic Pipe Ada...

Page 13: ...box Check the control box wiring diagram against the incoming power hookup Check drop cable color coding Reconnect the drop cable so the cable color code matches the motor lead color code There is a b...

Page 14: ...n the well while the pump is running and compare to the pump depth setting Lower the pump further into the well but at least 5 ft 1 6M above the bottom of the well Throttle the pump discharge until th...

Page 15: ...HOMEDEPOT COM 15 This page intentionally left blank Please contact 1 844 883 1872 for further assistance...

Page 16: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM Retain this manual for future use...

Page 17: ...oblemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente de Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM GRACIAS Apreciamos la...

Page 18: ...n tape para sellar las juntas en tuber a pl stica o tuber a de conexi n a las bombas termopl sticas ADVERTENCIA Advertencia de la Propuesta 65 de California Este producto contiene sustancias qu micas...

Page 19: ...ginal y la etiqueta de informaci n de la garant a La elegibilidad est basada en la fecha de compra del producto original y no en la fecha del reemplazo bajo la garant a La garant a est limitada a la r...

Page 20: ...voltaje de la bomba que seleccione coincida con el voltaje del pozo N MERO DE CABLES Y CAJAS DE CONTROL DE LA BOMBA Las bombas de 4 pulg se ofrecen con 2 cables o 3 cables el n mero de cables que sal...

Page 21: ...necte el cable de tierra a la tierra aprobada primero y luego conecte al equipo que se est instalando No haga la conexi n a tierra a una l nea de suministro de gas ADVERTENCIA Riesgo de choque el ctri...

Page 22: ...del cable HP Voltio Calibre del cable AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 0 75 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371 59...

Page 23: ...de 2 cables Las bombas de 2 cables tiene un cable de alimentaci n negro y un cable de tierra verde No se requiere caja de control Esta es informaci n de conexi n correcta para motores de 2 cables de 1...

Page 24: ...ta Cubre el cable unas 1 1 2 pulg 38 mm en cada lado de la junta Haga cuatro vueltas con la cinta Cuando haya terminado debe tener cuatro capas de cinta envueltas apretadamente alrededor del cable Pre...

Page 25: ...E ALIMENTACI N 1 Para probar la bomba sumergible con ctela moment neamente no m s de 30 segundos a la fuente de alimentaci n apropiada La frecuencia y voltaje de la fuente de alimentaci n deben coinci...

Page 26: ...rranque la bomba por primera vez NUNCA arranque una bomba con la descarga completamente abierta a menos que haya hecho primero este procedimiento 1 Conecte un codo de tuber a una corta longitud de tub...

Page 27: ...de presi n contra el congelamiento ACOPLAMIENTO DEL TANQUE DE PRESI N PRECARGADO Este diagrama muestra una instalaci n sumergible t pica con una instalaci n de tanque precargado AVISO Los motores de...

Page 28: ...conexi n el ctrica Pre cargado el tanque El nivel del suelo Conducto o manga Adaptador de tuber a de pl stico Cable de alimentaci n Cinta de nylon Empalmes de cables Gu a de centrado Adaptador de tube...

Page 29: ...codificaci n por color del cable de ca da Vuelva a conectar el cable de ca da de modo que el c digo de color del cable coincida con el c digo de color del conductor del motor Hay un cable roto en la c...

Page 30: ...mientras la bomba est funcionando y compare con el ajuste de profundidad de la bomba Baje m s la bomba al pozo pero al menos 5 pies 1 6 m sobre el fondo del pozo Estrangule la descarga de la bomba has...

Page 31: ...HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional esta p gina est en blanco 15...

Page 32: ...8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM Conserve este manual para uso futuro Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente...

Reviews: