Everbilt EFSUB10-122HD Use And Care Manual Download Page 18

Tabla de contenido 

 

 

 

Tabla de contenido ....................................................... 2

 

Información de seguridad ............................................ 2

 

Garantía .......................................................................... 3

 

Pre-instalación .............................................................. 3

 

Conexiones del cableado ............................................. 5

 

Instalación ...................................................................... 8

 

Empalme del cable ..................................................................8

 

Instalación del cable de la fuente de alimentación..................9

 

Instalación de la bomba .........................................................10

 

Arranque inicial/pozos nuevos ...............................................10

 

Conexión al tanque/sistema de agua .....................................11

 

Resolución de fallas ................................................... 13

 

Información de seguridad 

 

INSTRUCCIONES DE SEGURIDAD IMPORTANTES 

GUARDE ESTAS INSTRUCCIONES – Este manual contiene instrucciones 
importantes que deben respetarse durante la instalación, operación 
y mantenimiento de esta bomba. También, familiarícese con los 
siguientes símbolos de seguridad y sus significados: 

 

PELIGRO: 

Indica una situación peligrosa que, si no se 

evita, resultará en la muerte o lesiones graves.

 

 

 

ADVERTENCIA: 

Indica una situación peligrosa que, si no 

se evita, podría resultar en la muerte o lesiones graves.

 

 

 

PRECAUCIÓN: 

Indica una situación peligrosa que, si no 

se evita, podría resultar en lesiones menores o moderadas .

 

 

AVISO: 

Aborda prácticas no relacionadas con lesiones personales.

 

 

Lea cuidadosamente y respete todas las instrucciones  
de seguridad en este manual y en la bomba.

 

Mantenga las etiquetas de seguridad en buenas condiciones. 
Reemplace las etiquetas de seguridad faltantes o dañadas. 

1.

 

Instale la bomba de acuerdo con todos los requisitos 
del código de fontanería, bomba y pozo. 

2.

 

Pruebe el agua del pozo en cuanto a pureza antes de 
usar el pozo. Llame a su departamento de salud local 
para obtener procedimientos de pruebas. 

3.

 

Durante la instalación, mantenga cubierto lo más posible 
el pozo para evitar que caigan al pozo hojas y material 
extraño. Los objetos extraños en el pozo pueden 
contaminar el agua y ocasionar daños mecánicos 
serios a la bomba. 

4.

 

El compuesto de juntas de tuberías puede causar 
agrietamiento en los plásticos. Use solo cinta Teflón 
tape para sellar las juntas en tubería plástica  
o tubería de conexión a las bombas termoplásticas. 

 

ADVERTENCIA: 

Advertencia de la Propuesta 65 de 

California:

 Este producto contiene sustancias químicas que 

el Estado de California sabe producen cáncer, defectos de 

nacimiento u otros daños reproductivos.

 

 

 

ADVERTENCIA: 

Riesgo de presión peligrosa.

 Bajo ciertas 

condiciones, las bombas sumergibles pueden desarrollar 
presiones extremadamente altas. Instale una válvula de alivio 

de presión capaz de dejar pasar todo el flujo de la bomba  
a 75 PSI (517 kPa) cuando use un tanque de presión de agua 

con aire sobre.  Instale una válvula de alivio de presión capaz 
de dejar pasar todo el flujo de la bomba a 100 PSI (690 kPa) 

cuando use un tanque de presión precargado.

 

 

 

ADVERTENCIA: 

Riesgo de choque eléctrico.

 Puede 

dar un choque, quemar o matar. Para evitar el riesgo de  

un choque choque eléctrico peligroso o fatal, use la bomba 
únicamente en un pozo de agua.

 

 

 

ADVERTENCIA: 

Riesgo de choque eléctrico.

 Puede 

dar un choque, quemar o matar. No instale esta bomba en 

un estanque, río, u otro cuerpo de agua abierto que podría 
ser usado para natación o recreación.  No nade, no camine, 

ni juegue en un cuerpo de agua en el cual se ha instalado 
una bomba sumergible.

 

 

 

ADVERTENCIA: 

Instale, conecte a tierra y cablee la bomba 

de acuerdo a los requisitos del código local y el Código 

Eléctrico Nacional.

 

 

 

ADVERTENCIA: 

Desconecte la fuente de energía 

eléctrica antes de instalar o darle servicio a la bomba.

 

 

 

ADVERTENCIA: 

Asegúrese de que el voltaje de la línea  

y la frecuencia de la fuente de alimentación coincidan con 
el voltaje y frecuencia de la placa de identificación del motor.

 

 

 

PRECAUCIÓN: 

Riesgo de inundación: 

Puede causar 

lesiones personales y/o daños a la propiedad. No permita 
que se congele el agua que contiene la bomba, el tanque  

de presión o cualquier otro componente del sistema.  
El congelamiento puede dañar el sistema, conduciendo  

a lesiones o inundación. Dejar que la bomba o componentes 
del sistema se congelen anulará la garantía. 

 

 

Summary of Contents for EFSUB10-122HD

Page 1: ...rovement needs Thank you for choosing Everbilt Item 1001 092 349 1001 092 255 1001 092 261 1001 092 264 1001 092 483 1001 092 258 1001 092 273 Model EFSUB5 122HD EFSUB5 123HD EFSUB7 122HD EFSUB7 123HD...

Page 2: ...cause cracking in plastics Use only Teflon tape when sealing joints in plastic pipe or connecting pipe to thermoplastic pumps WARNING California Proposition 65 Warning This product and related accesso...

Page 3: ...ranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to r...

Page 4: ...ches the voltage of the well NUMBER OF PUMP WIRES AND CONTROL BOXES 4 in pumps are offered in either 2 wire or 3 wire the number of wires running from the pump motor 2 wire motors have 3 wires running...

Page 5: ...ons for wire splicing instructions Permanently ground the pump motor and control box before connecting the power cable to power supply Connect the ground wire to the approved ground first and then con...

Page 6: ...Wire Cable 60 Hz Wire Size HP Volt Wire Size AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371...

Page 7: ...olor coding when connecting control box Yellow to Y Red to R Black to B Single phase 2 wire connections 2 wire pumps have two power supply wire Black and one ground wire Green Control box is not requi...

Page 8: ...1 1 2 in 38 mm on each side of the joint Make four passes with the tape When finished you should have four layers of tape tightly wrapped around the wire Press edges of tape firmly down against the w...

Page 9: ...or body and tighten by hand for a strong waterproof splice POWER SUPPLY WIRE INSTALLATION 1 To test submersible momentarily no more than 30 seconds connect it to the proper power supply Power supply f...

Page 10: ...low the procedure below when starting the pump for the first time NEVER start a pump with the discharge completely open unless you have done this procedure first 1 Connect a pipe elbow a short length...

Page 11: ...ill void the warranty Protect the pump and entire piping system including pressure tank from freezing PRE CHARGED PRESSURE TANK HOOKUP This diagram shows a typical submersible installation with a pre...

Page 12: ...kPa Control box 3 wire models only Electrical Disconnect Box Pre Charged Tank Ground Level Conduit or Sleeve Plastic Pipe Adapter Power Cable Nylon Tape Cable Splices Centering Guide Plastic Pipe Ada...

Page 13: ...box Check the control box wiring diagram against the incoming power hookup Check drop cable color coding Reconnect the drop cable so the cable color code matches the motor lead color code There is a b...

Page 14: ...n the well while the pump is running and compare to the pump depth setting Lower the pump further into the well but at least 5 ft 1 6M above the bottom of the well Throttle the pump discharge until th...

Page 15: ...HOMEDEPOT COM 15 This page intentionally left blank Please contact 1 844 883 1872 for further assistance...

Page 16: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM Retain this manual for future use...

Page 17: ...oblemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente de Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM GRACIAS Apreciamos la...

Page 18: ...n tape para sellar las juntas en tuber a pl stica o tuber a de conexi n a las bombas termopl sticas ADVERTENCIA Advertencia de la Propuesta 65 de California Este producto contiene sustancias qu micas...

Page 19: ...ginal y la etiqueta de informaci n de la garant a La elegibilidad est basada en la fecha de compra del producto original y no en la fecha del reemplazo bajo la garant a La garant a est limitada a la r...

Page 20: ...voltaje de la bomba que seleccione coincida con el voltaje del pozo N MERO DE CABLES Y CAJAS DE CONTROL DE LA BOMBA Las bombas de 4 pulg se ofrecen con 2 cables o 3 cables el n mero de cables que sal...

Page 21: ...necte el cable de tierra a la tierra aprobada primero y luego conecte al equipo que se est instalando No haga la conexi n a tierra a una l nea de suministro de gas ADVERTENCIA Riesgo de choque el ctri...

Page 22: ...del cable HP Voltio Calibre del cable AWG 14 12 10 8 6 4 3 2 1 0 00 0 5 230 359 571 912 1444 2246 3581 4502 5685 7162 9040 0 75 230 281 447 713 1129 1757 2800 3521 4446 5601 7070 8920 1 230 233 371 59...

Page 23: ...de 2 cables Las bombas de 2 cables tiene un cable de alimentaci n negro y un cable de tierra verde No se requiere caja de control Esta es informaci n de conexi n correcta para motores de 2 cables de 1...

Page 24: ...ta Cubre el cable unas 1 1 2 pulg 38 mm en cada lado de la junta Haga cuatro vueltas con la cinta Cuando haya terminado debe tener cuatro capas de cinta envueltas apretadamente alrededor del cable Pre...

Page 25: ...E ALIMENTACI N 1 Para probar la bomba sumergible con ctela moment neamente no m s de 30 segundos a la fuente de alimentaci n apropiada La frecuencia y voltaje de la fuente de alimentaci n deben coinci...

Page 26: ...rranque la bomba por primera vez NUNCA arranque una bomba con la descarga completamente abierta a menos que haya hecho primero este procedimiento 1 Conecte un codo de tuber a una corta longitud de tub...

Page 27: ...de presi n contra el congelamiento ACOPLAMIENTO DEL TANQUE DE PRESI N PRECARGADO Este diagrama muestra una instalaci n sumergible t pica con una instalaci n de tanque precargado AVISO Los motores de...

Page 28: ...conexi n el ctrica Pre cargado el tanque El nivel del suelo Conducto o manga Adaptador de tuber a de pl stico Cable de alimentaci n Cinta de nylon Empalmes de cables Gu a de centrado Adaptador de tube...

Page 29: ...codificaci n por color del cable de ca da Vuelva a conectar el cable de ca da de modo que el c digo de color del cable coincida con el c digo de color del conductor del motor Hay un cable roto en la c...

Page 30: ...mientras la bomba est funcionando y compare con el ajuste de profundidad de la bomba Baje m s la bomba al pozo pero al menos 5 pies 1 6 m sobre el fondo del pozo Estrangule la descarga de la bomba has...

Page 31: ...HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional esta p gina est en blanco 15...

Page 32: ...8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM Conserve este manual para uso futuro Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente...

Reviews: