Parameter Specification Table
10-1
605 Series Frequency Inverter
10
P
ARAMETER
S
PECIFICATION
T
ABLE
The headings for the Tag No. table are described below.
Tag
Tag
Tag
Tag
A numeric identification of the parameter. It is used to identify the source and
destinations of internal links.
Name
Name
Name
Name
The parameter name as it appears on the MMI.
Block
Block
Block
Block
The menu page and function block under which the parameter is stored.
Type
Type
Type
Type
INT A numeric value that may be positive or negative. INT types may
have decimal places
BOOL A Boolean (bit) representing FALSE or TRUE
ENUM An enumerated value representing a selection
STRING An ASCII string
TAG A value representing a choice of TAG
D_TAG A value representing a choice of Destination tag as an internal
link
S_TAG A value representing a choice of Source tag as an internal link
WORD 16 Bit hexadecimal number
Range
Range
Range
Range
This varies with parameter type:
INT The upper and lower limits of the parameter, indicating the
parameter’s true, internally-held, number of decimal (a reduced
number of digits may be shown by the Operator Station).
BOOL 0 = FALSE, 1 = TRUE
ENUM A list of possible selections for that parameter
STRING Specified number of characters
TAG The tag number of any parameter
D_TAG The tag number of an input parameter
S_TAG The tag number of an input or output parameter.
(May be set to a negative value indicating a feedback link).
WORD 0000 to FFFF (hexadecimal)
ID
ID
ID
ID
Serial Communications Mnemonic:
Refer to Chapter 14: “Serial Communications”
Notes
Notes
Notes
Notes
You can record your application’s settings here.
Output parameters are not saved in non-volatile memory.
1. This input parameter is not saved in non-volatile memory.
2. This parameter is automatically saved in non-volatile memory.
3. This parameter forms part of the motor configuration.
4. This parameter is not adjustable from the operator station.
5. This parameter cannot be the destination of a link.
6. This parameter cannot be the source of a link.
7. This parameter can only be written to when the Inverter is stopped.
8. This parameter can only be written to when the Inverter is in configuration
mode.
Summary of Contents for 605 Series
Page 16: ...1 4 Getting Started 605 Series Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605 Series Frequency Inverter ...
Page 34: ...3 12 Installing the Inverter 605 Series Frequency Inverter ...
Page 48: ...4 14 Operating the Inverter 605 Series Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605 Series Frequency Inverter ...
Page 198: ...12 12 Certification for the Inverter 605 Series Frequency Inverter ...
Page 202: ...13 4 Application Notes 605 Series Frequency Inverter ...
Page 204: ...14 2 Serial Communications 605 Series Frequency Inverter ...