6-76
Programming Your Application
605 Series Frequency Inverter
Operation
Operation
Operation
Operation
Description
Description
Description
Description
TIMER
Times the period elapsed from when INPUT A is set TRUE and held TRUE,
to when INPUT B becomes TRUE.
OUTPUT is the duration of the timer, starting from zero. If INPUT B is
TRUE, the value for OUTPUT is held until INPUT B is released. If on
release INPUT A is still TRUE, the timer will continue from the held value.
Setting INPUT A and INPUT B to FALSE resets the timer.
INPUT C is not used.
MINIMUM
PULSE
Creates an output pulse of adjustable minimum time when INPUT A is
TRUE. (INPUT A is assumed to be a sequence of TRUE pulses and FALSE
off periods.)
INPUT B sets the length of the minimum pulse required. INPUT C inverts
the output when TRUE. The duration of the pulse is
at least
the period set by
INPUT B.
input A
input B
output
input A
output
input C FALSE
input C TRUE
Duration (input B)
t
input B