10.
After finishing setting the time table, Press 'Save'.
Note: Do not pass the' SIM Swapping Limitation' of 400 time slots per port (see page 21).
6.2.2 Call Duration Mode
In this mode, you define a list of SIMs that will work at the port that day. Each SIM will work for a
number of predefined units. In the SIM profile you define how many units each interval of time
will count for.
Each day the gateway will register the first SIM on the list for that day, the gateway will count
down the units of the SIM until thy reach 0(Zero). The gateway will then register the next SIM on
the list, until all the SIM finish their units.
At the beginning at the month (or the beginning of the week when 'Type' is set to 'Weekly'), the
gateway will reset all the units of the SIMs to the original amounts so it can continue working
without setting again the time tables.
The calculation of the units per call
In the Virtual SIM window in the Profile you selected, in the 'SIM Prepaid', 'Charge Calculation',
'Billing', these are the call duration parameters:
•
Primary Bill Interval – The interval of time (in seconds) for the beginning of the call.
•
Primary Interval Count – The number of times the Primary Bill Interval will repeat.
•
Primary Cost per Bill Int – The amount of units the Primary Bill Interval will count for.
•
Secondary Bill Interval – The intervals of time (in seconds) after the end 'Primary Bill
Interval'.
•
Secondary Cost per Bill Int – The amount of units the Secondary Bill Interval will count
for.
At the beginning of the call the gateway will count the units according to the 'Primary Bill
Interval'. This interval will be counted 'Primary Interval Count' times. The rest of the call will use
the 'Secondary Bill Interval'.
.
Example of the unit's calculation:
Fig: Example of Call Duration settings
With these Billing parameters as in the figure above, we will make a call for 1 minute and 59
seconds. The unit's calculation of this call will be:
At the beginning of the call will count 2 times the 'Primary Bill Interval' that is 60 sec.
The charge calculation will be: 2 intervals of 2 units per interval = 4 units.
The rest of the call will take 3 interval of 'secondary Bill Interval' for 59 secs