EUROSTER Q7TXRXGW Installation And Operation Manual Download Page 6

EUROSTER Q7TXRX

GW

 

 INSTALLATION AND OPERATION MANUAL

 

6

 

 

 

Select  digits  of  the  current  date  and  hour,  and  confirm  each  of  them  subsequently.  The 
following is set respectively: 

 

last two digits of year 

 

month 

 

day 

 

hour 

 

minutes. 

After  confirming  minutes,  the  thermostat  updates  the  entered  date  and  the  service  menu 
may be exited or other functions may be selected. 
 

b.

 

Factory-set ranges

 

The  thermostat  is  provided  with  the  factory-programmed  ranges,  which  may  be  freely 
adjusted  and  deleted.  In  case  of  resetting  (item 311)  all  current  ranges  are  replaced  with 
the factory settings.

 

Heating: 

Cooling:

 

Mon-Thu

 

P1 21ºC 06:00 am –

 08:30 am

 

P2 18ºC 08:30 am –

 04:00 pm

 

P3 21ºC 04:00 pm –

 11:00 pm

 

P4 17ºC 11:00 pm –

 06:00 am

 

Fri

 

P1 21ºC 06:00 am –

 08:30 am

 

P2 18ºC 08:30 am –

 04:00 pm

 

P3 21ºC 04:00 pm –

 11:00 pm

 

P4 17ºC 11:00 pm –

 08:00 am

 

Sat

 

P1 21ºC 08:00 am –

 11:00 pm

 

P2 17ºC 11:00 pm –

 08:00 am

 

Sun 

 

P1 21ºC 08:00 am –

 11:00 pm

 

P2 17ºC 11:00 pm –

 06:00 am

 

Mon-Fri

 

P1 23ºC 06:00 am –

 08:30 am

 

P2 28ºC 08:30 am –

 03:00 pm

 

P3 22ºC 03:

00 pm 

 11:00 pm

 

P4 25ºC 11:00 pm –

 06:00 am

 

Sat-Sun

 

P1 23ºC 06:00 am –

 11:00 am

 

P2 22ºC 11:00 am –

 04:00 pm

 

P3 23ºC 04:00 pm –

 11:00 pm

 

P4 25ºC 11:00 pm –

 06:00 am

 

c.

 

Learning

 

The  learning  mode  enables  automatic  storing  of  periodically  repeated  manual  temperature 
settings.  Based  on  them  the  thermostat  creates  ranges  with  suitable  temperatures.  It 
enables  avoiding  laborious  programing.  Based  on  manually  input  temperature  settings  the 
thermostat creates their time ranges. Separate ranges are created for weekdays (Mon-Fri), 
separate for weekends (Sat-Sun) and for single days of the week when a given temperature 
is set  on the same day for two subsequent weeks (e.g. the same time on two  subsequent 
Mondays). 

The time when the temperature was set and the temperature itself do not have to be exactly 
the same. For a full description see: section III. Service functions.

 

In order to activate the learning mode, enter SERVICE (3) menu / LEARNING (item 
306), select: YES and confirm. 

d.

 

Heating in advance

 

 

Heating  a  room  in  advance,  which  enables  reaching  the  preset  temperature  on  required 
time.

 

Summary of Contents for Q7TXRXGW

Page 1: ...TAT MAINTENANCE Do not use the thermostat in rooms with excessive humidity significant dustiness or with presence of caustic or flammable vapors If necessary wipe it carefully with a damp cloth Do not...

Page 2: ...e battery compartment II USER FUNCTIONS 1 CONTROL OF THE THERMOSTAT a Display icons and operating window 1 Hour 2 Strength of radio communication between the thermostat and the receiver 3 Text box 4 C...

Page 3: ...fter pressing OK shortly when the display backlight is switched off If the thermostat cooperates with several receivers then the displayed signal strength is the signal strength of the most distant th...

Page 4: ...sensor only e RX receiver The receiver is equipped with a pass through socket enabling connecting a boiler or other device to the power supply It is not a controllable socket It is a simple 230 V soc...

Page 5: ...A will be displayed and the connected device will be switched on for 20 minutes every 3 h 2 BASIC SETTINGS The main menu consists of three basic items MODES 1 PROGRAMS 2 SERVICE 3 The menu items with...

Page 6: ...P1 23 C 06 00 am 08 30 am P2 28 C 08 30 am 03 00 pm P3 22 C 03 00 pm 11 00 pm P4 25 C 11 00 pm 06 00 am Sat Sun P1 23 C 06 00 am 11 00 am P2 22 C 11 00 am 04 00 pm P3 23 C 04 00 pm 11 00 pm P4 25 C 1...

Page 7: ...24 h The thermostat provides two methods of manual temperature setting a First method selecting an exact temperature for one of the three preset duration values It enables selecting the exact temperat...

Page 8: ...ll days of the week 1 2 3 4 5 6 7 are flashing Select the proper day or group of days and confirm After selecting the device will automatically proceed to the next item EDIT item 202 b EDIT item 202 p...

Page 9: ...se remember there will be a pause in heating in the place of the deleted range Adding a new range with starting and ending hours completely overlapping another range also deletes the previous one A ra...

Page 10: ...TO mode Detection of a rapid drop of ambient temperature switches the heating device off for the preset time If frost protection temperature is not switched on item 308 NO then airing mode limits the...

Page 11: ...mes and temperatures to be selected with the button see II User functions point 3 TEMPERATURE three temperatures of manual setting factory setting 18 C 20 C and 22 C DURATION three duration values of...

Page 12: ...as established and repeated When learning is active item 306 YES the thermostat records the temperature and time when it was modified If similar temperatures differing by no more than 0 4 C will be se...

Page 13: ...g days to properly calculate times for various temperatures thus for the first days the calculated times may not be enough to achieve precisely the preset temperatures at established times Usually the...

Page 14: ...he settings entered in the technician s menu neither does it reset the date and time It deletes all settings in the SERVICE menu along with the programmed ranges 12 AIR CONDITIONING item 312 switch fr...

Page 15: ...y algorithms to the particular configuration without the need to modify them manually in the service menu RADIO item 3 enables pairing devices establishing number of transmitters or receivers assignin...

Page 16: ...mperature drops below the preset one in the three rooms with thermostats no 1 2 and 3 When turn off if any is set and no 4 is selected then the receiver will switch on the heating if the preset temper...

Page 17: ...sh the priorities and possibly select a channel In order to pair Enter PAIR item and press OK WAIT will be displayed Then hold the left button of the RX receiver for 3 s PROG will be displayed Then ho...

Page 18: ...he need to change over the cables push the right button shortly To switch on pairing hold the middle button longer To exit hold the left button longer V INSTALLATION AND CONNECTION 1 PROPER PLACE OF I...

Page 19: ...rate the front panel and the base 3 SAMPLE CONNECTION DIAGRAMS The following diagrams are simplified and do not cover all the elements necessary for the correct installation In arrangement with a 230...

Page 20: ...INSTALLATION AND OPERATION MANUAL 20 In arrangement with a central heating pump 1 CH boiler 2 CH pump 3 Heat consumer radiator 4 Electrical connection block 5 Euroster RXGW 6 Euroster Q7TX 7 Output c...

Page 21: ...e Mounting method thermostat stand receiver 230 V 50 Hz socket Thermostat weight without batteries thermostat without batteries 114 g receiver 359 g Warranty period 2 years Dimensions W H D mm the the...

Page 22: ...may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or maki...