EUROSTER Q7TXRX
GW
–
INSTALLATION AND OPERATION MANUAL
15
IV. TECHNICIAN'S MENU
–
quick start
The technician's menu facilitates installing the thermostat with proper settings without the
need to modify them manually.
In order to enter these settings, hold OK. When SETUP appears, hold OK and turn the knob.
INSTALL will appear.
1.
The technician's menu consists of the following elements:
•
RESET (item 1)
–
using it deletes all settings and restores the thermostat factory
settings, including the installation settings and default interlock code. It is
recommended to consult a technician or EUROSTER technical service prior to
resetting the device. Reset is implemented with a separate code: 7153, irrespective
of the code set in the service menu.
Caution! Restoring factory settings may lead to improper operation of the
heating device and in extreme cases it may lead to a failure or damage of
the system.
•
INSTALL (item 2)
–
enables selection of the following:
•
language,
•
type of system: heating
–
air-conditioning (heats
–
cools down),
•
heat sources (water
–
electricity),
•
heating elements (radiators, floor or forced air) and
•
devices switched on by the thermostat (pump, valve, boiler or others).
Setting these options enables selection of preliminary settings, mainly algorithms, to
the particular configuration without the need to modify them manually in the service
menu.
•
RADIO (item 3)
–
enables pairing devices, establishing number of transmitters or
receivers, assigning priorities to transmitters and copying the settings to / from RX
modules (see: point 2).
•
TEST (item 4)
–
enables checking of the following:
•
software version,
•
correct switching on and off for the receiver,
•
display,
•
signal strength,
•
temperature measurement.
In order to check the correct connection of the heating device to the receiver output,
press OK
–
the receiver will be switched on. Then press OK again
–
the receiver is
switched off.
2.
DETAILED DESCRIPTION OF RADIO SETTINGS
a.
NEXT ITEM
–
One Q7RX receiver (in a socket) may be switched on and off by several
Q7TX thermostats (a unit with batteries), maximum of 6 pcs.
Switching on and off may be conditioned. It consists in establishing priorities determining
which thermostats switch the device on and which switch it off and whether a selected one
or all of them should switch the device on /off.
In order to do so, it is necessary to distinguish the thermostats by assigning a proper no. to
each of them: from 1 to 6. A default setting is 1. Thermostat no. 1 is the main thermostat
and the only one enabled to program all other radio functionalities. If no. 2 or higher is
selected, the thermostat proceeds immediately to pairing the thermostat with the receiver.
PAIR is displayed in the text box.