EUROSTER Q7TXRXGW Installation And Operation Manual Download Page 5

EUROSTER Q7TXRX

GW

 

 INSTALLATION AND OPERATION MANUAL

 

5

 

 

 

If  several  thermostats  cooperate  with  one  RX  receiver,  then  the  receiver  display  will 
alternately show the information concerning all of the thermostats. 
First  of  all,  digit  1  (designating  thermostat  number  one)  is  displayed  followed  by  the 
temperature measured with thermostat number one, then digit 2 is visible followed by the 
temperature measured with thermostat number two, etc. 
If the receiver does not receive a signal  confirming the  operation  of the thermostat within 
15 minutes, the receiver(s) switches off the heating and reverts to the fail safe mode. Letter 
A will be displayed and the connected device will be switched on for 20 minutes every 3 h.

 

2.

 

BASIC SETTINGS

 

The main menu consists of three basic items: 

 

MODES (1) 
PROGRAMS (2) 
SERVICE (3)

 

The menu items with numbers assigned to them are listed in the table below. 

ITEM 
NO. 

MENU ITEM 

ITEM NO.  MENU ITEM

 

MODES 

101 

VACATION 

 

102 

AIRING 

 

103 

PARTY 

 

104 

HOLD

 

105 

ECO

 

106 

EXIT

 

PROGRAMS 

201 

DAY

 

202 

EDIT

 

203 

COPY

 

204 

EXIT

 

SERVICE 

301 

OPERATING TIME

 

302 

MANUAL SETTING

 

303 

MODES

 

304 

YEAR TIME

 

305 

ALGORITHM

 

306 

LEARNING

 

307 

HEATING IN ADVANCE 

 

308 

ANTI-FREEZE PROTECTION

 

309 

CORRECTION OF SENSORS

 

310 

PIN

 

311 

RESETTING

 

312 

AIR-CONDITIONING

 

313 

EXIT

 

EXIT

 

The following section describes the most useful functions for users. 

a.

 

Date and time

 

In  order  to  set  the  time  and  date,  enter  SERVICE  (item 3)  menu  and  select  YEAR  TIME 
(item 304). 

Summary of Contents for Q7TXRXGW

Page 1: ...TAT MAINTENANCE Do not use the thermostat in rooms with excessive humidity significant dustiness or with presence of caustic or flammable vapors If necessary wipe it carefully with a damp cloth Do not...

Page 2: ...e battery compartment II USER FUNCTIONS 1 CONTROL OF THE THERMOSTAT a Display icons and operating window 1 Hour 2 Strength of radio communication between the thermostat and the receiver 3 Text box 4 C...

Page 3: ...fter pressing OK shortly when the display backlight is switched off If the thermostat cooperates with several receivers then the displayed signal strength is the signal strength of the most distant th...

Page 4: ...sensor only e RX receiver The receiver is equipped with a pass through socket enabling connecting a boiler or other device to the power supply It is not a controllable socket It is a simple 230 V soc...

Page 5: ...A will be displayed and the connected device will be switched on for 20 minutes every 3 h 2 BASIC SETTINGS The main menu consists of three basic items MODES 1 PROGRAMS 2 SERVICE 3 The menu items with...

Page 6: ...P1 23 C 06 00 am 08 30 am P2 28 C 08 30 am 03 00 pm P3 22 C 03 00 pm 11 00 pm P4 25 C 11 00 pm 06 00 am Sat Sun P1 23 C 06 00 am 11 00 am P2 22 C 11 00 am 04 00 pm P3 23 C 04 00 pm 11 00 pm P4 25 C 1...

Page 7: ...24 h The thermostat provides two methods of manual temperature setting a First method selecting an exact temperature for one of the three preset duration values It enables selecting the exact temperat...

Page 8: ...ll days of the week 1 2 3 4 5 6 7 are flashing Select the proper day or group of days and confirm After selecting the device will automatically proceed to the next item EDIT item 202 b EDIT item 202 p...

Page 9: ...se remember there will be a pause in heating in the place of the deleted range Adding a new range with starting and ending hours completely overlapping another range also deletes the previous one A ra...

Page 10: ...TO mode Detection of a rapid drop of ambient temperature switches the heating device off for the preset time If frost protection temperature is not switched on item 308 NO then airing mode limits the...

Page 11: ...mes and temperatures to be selected with the button see II User functions point 3 TEMPERATURE three temperatures of manual setting factory setting 18 C 20 C and 22 C DURATION three duration values of...

Page 12: ...as established and repeated When learning is active item 306 YES the thermostat records the temperature and time when it was modified If similar temperatures differing by no more than 0 4 C will be se...

Page 13: ...g days to properly calculate times for various temperatures thus for the first days the calculated times may not be enough to achieve precisely the preset temperatures at established times Usually the...

Page 14: ...he settings entered in the technician s menu neither does it reset the date and time It deletes all settings in the SERVICE menu along with the programmed ranges 12 AIR CONDITIONING item 312 switch fr...

Page 15: ...y algorithms to the particular configuration without the need to modify them manually in the service menu RADIO item 3 enables pairing devices establishing number of transmitters or receivers assignin...

Page 16: ...mperature drops below the preset one in the three rooms with thermostats no 1 2 and 3 When turn off if any is set and no 4 is selected then the receiver will switch on the heating if the preset temper...

Page 17: ...sh the priorities and possibly select a channel In order to pair Enter PAIR item and press OK WAIT will be displayed Then hold the left button of the RX receiver for 3 s PROG will be displayed Then ho...

Page 18: ...he need to change over the cables push the right button shortly To switch on pairing hold the middle button longer To exit hold the left button longer V INSTALLATION AND CONNECTION 1 PROPER PLACE OF I...

Page 19: ...rate the front panel and the base 3 SAMPLE CONNECTION DIAGRAMS The following diagrams are simplified and do not cover all the elements necessary for the correct installation In arrangement with a 230...

Page 20: ...INSTALLATION AND OPERATION MANUAL 20 In arrangement with a central heating pump 1 CH boiler 2 CH pump 3 Heat consumer radiator 4 Electrical connection block 5 Euroster RXGW 6 Euroster Q7TX 7 Output c...

Page 21: ...e Mounting method thermostat stand receiver 230 V 50 Hz socket Thermostat weight without batteries thermostat without batteries 114 g receiver 359 g Warranty period 2 years Dimensions W H D mm the the...

Page 22: ...may be repaired exclusively by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or maki...

Reviews: